GC-MIP-PED AS AN ELEMENT-SPECIFIC SYSTEM FOR THE DETERMINATION OF ORGANOMERCURY COMPOUNDS

被引:12
作者
BETTMER, J
BRADTER, M
BUSCHER, W
ERBER, D
RIEPING, D
CAMMANN, K
机构
[1] Institut Für Chemo- Und Biosensorik E.V, Westfälische Wilhelms-Universität Münster, Münster, D-48149
关键词
ORGANOMERCURY COMPOUNDS; GAS CHROMATOGRAPHY; MICROWAVE INDUCED PLASMA; ATOMIC EMISSION SPECTROMETRY;
D O I
10.1002/aoc.590090707
中图分类号
O69 [应用化学];
学科分类号
081704 ;
摘要
The application of the combination of gas chromatography and a self-developed plasma emission detector for organomercury speciation is presented, The system, basing on interference filter technology, is described briefly. The plasma and the optical system have to be optimized to reach highest sensitivity for mercury detection. Dimethyl-, methyl- and inorganic mercury as selected compounds have been separated on a GC column and calibrated to obtain the analytical performance data of the system used. Finally, the analysis of some real samples has been performed.
引用
收藏
页码:541 / 545
页数:5
相关论文
共 16 条
[1]   CAVITY FOR MICROWAVE-INDUCED PLASMAS OPERATED IN HELIUM AND ARGON AT ATMOSPHERIC-PRESSURE [J].
BEENAKKER, CIM .
SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 1976, 31 (8-9) :483-486
[3]  
BRADTER MW, 1989, MIKROCHIM ACTA, V3, P215
[4]  
CAMMANN K, 1992, ACS SYM SER, V479, P105
[5]   REDUCED CALIBRATION EFFORTS IN GAS-CHROMATOGRAPHY BY THE USE OF AN ELEMENT-SELECTIVE PLASMA-EMISSION DETECTOR [J].
CAMMANN, K ;
MULLER, H .
FRESENIUS ZEITSCHRIFT FUR ANALYTISCHE CHEMIE, 1988, 331 (3-4) :336-341
[6]   A COMPARATIVE-STUDY OF GAS-CHROMATOGRAPHY WITH ATOMIC-ABSORPTION AND ATOMIC EMISSION DETECTION FOR THE SPECIATION ANALYSIS OF ORGANOTIN [J].
DIRKX, W ;
LOBINSKI, R ;
ADAMS, FC .
ANALYTICAL SCIENCES, 1993, 9 (02) :273-278
[7]   THE WICKBOLD COMBUSTION METHOD FOR THE DETERMINATION OF MERCURY UNDER STATISTICAL ASPECTS [J].
ERBER, D ;
QUICK, L ;
WINTER, F ;
ROTH, J ;
CAMMANN, K .
FRESENIUS JOURNAL OF ANALYTICAL CHEMISTRY, 1994, 349 (07) :502-509
[8]  
LOBINSKI R, 1994, ANALUSIS, V22, P37
[9]   OPTIMIZATION OF COMPREHENSIVE SPECIATION OF ORGANOTIN COMPOUNDS IN ENVIRONMENTAL-SAMPLES BY CAPILLARY GAS-CHROMATOGRAPHY HELIUM MICROWAVE-INDUCED PLASMA EMISSION-SPECTROMETRY [J].
LOBINSKI, R ;
DIRKX, WMR ;
CEULEMANS, M ;
ADAMS, FC .
ANALYTICAL CHEMISTRY, 1992, 64 (02) :159-165
[10]   EVALUATION OF A MICROWAVE CAVITY, DISCHARGE-TUBE, AND GAS-FLOW SYSTEM FOR COMBINED GAS-CHROMATOGRAPHY ATOMIC EMISSION DETECTION [J].
QUIMBY, BD ;
SULLIVAN, JJ .
ANALYTICAL CHEMISTRY, 1990, 62 (10) :1027-1034