LIMITATIONS AND LATE COMPLICATIONS OF 3RD-GENERATION AUTOMATIC CARDIOVERTER-DEFIBRILLATORS

被引:106
作者
NUNAIN, SO
ROELKE, M
TROUTON, T
OSSWALD, S
KIM, YH
SOSASUAREZ, G
BROOKS, DR
MCGOVERN, B
GUY, M
TORCHIANA, DF
VLAHAKES, GJ
GARAN, H
RUSKIN, JN
机构
[1] MASSACHUSETTS GEN HOSP,BOSTON,MA 02114
[2] HARVARD UNIV,SCH MED,CARDIAC ARRHYTHMIA SERV,BOSTON,MA
[3] HARVARD UNIV,SCH MED,CARDIAC SURG SERV,BOSTON,MA
关键词
PACING; DEFIBRILLATORS; ARRHYTHMIA; DEFIBRILLATION;
D O I
10.1161/01.CIR.91.8.2204
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background This study examines the limitations and complex management problems associated with the use of tiered-therapy, implantable cardioverter-defibrillators (ICDs). Methods and Results The study group comprises the first 154 patients undergoing implantation of tiered-therapy ICDs at our institution. Pulse generators from three different manufacturers were used. In 39 patients, a complete nonthoracotomy lead system was used. The perioperative mortality was 1.3%. Of these 154 patients, 37% experienced late postoperative problems. Twenty-one patients required system revision within 36.5 months (mean, 8.57+/-11.3) of surgery. Reasons for revision were spurious shocks due to electrode fractures (3) or electrode adapter malfunction (2), inadequate signal from endocardial rate-sensing electrodes (3), superior vena cava or right ventricular coil migration (5), failure to correct tachyarrhythmias due to a postimplant rise in defibrillation threshold (5), or pulse generator failure (3). One of these patients required system removal for infection after revision of an endocardial lead. A further 32 patients received inappropriate shocks for atrial fibrillation with a rapid ventricular response or sinus tachycardia. Two of these patients also received shocks for ventricular tachycardia initiated by antitachycardia pacing triggered by atrial fibrillation. Ventricular pacing for bradycardia was associated with inappropriate shocks due to excessive autogain in 2 patients. Conclusions Despite the major diagnostic and therapeutic advantages of tiered-therapy ICDs, a significant proportion of patients continue to experience hardware-related complications or receive inappropriate shocks.
引用
收藏
页码:2204 / 2213
页数:10
相关论文
共 25 条
[1]   A SIMPLIFIED, SINGLE-LEAD UNIPOLAR TRANSVENOUS CARDIOVERSION-DEFIBRILLATION SYSTEM [J].
BARDY, GH ;
JOHNSON, G ;
POOLE, JE ;
DOLACK, GL ;
KUDENCHUK, PJ ;
KELSO, D ;
MITCHELL, R ;
MEHRA, R ;
HOFER, B .
CIRCULATION, 1993, 88 (02) :543-547
[2]   CLINICAL-EXPERIENCE WITH A TIERED-THERAPY, MULTIPROGRAMMABLE ANTIARRHYTHMIA DEVICE [J].
BARDY, GH ;
TROUTMAN, C ;
POOLE, JE ;
KUDENCHUK, PJ ;
DOLACK, GL ;
JOHNSON, G ;
HOFER, B .
CIRCULATION, 1992, 85 (05) :1689-1698
[3]   IMPLANTABLE TRANSVENOUS CARDIOVERTER-DEFIBRILLATORS [J].
BARDY, GH ;
HOFER, B ;
JOHNSON, G ;
KUDENCHUK, PJ ;
POOLE, JE ;
DOLACK, GL ;
GLEVA, M ;
MITCHELL, R ;
KELSO, D .
CIRCULATION, 1993, 87 (04) :1152-1168
[4]   PACED BEATS FOLLOWING SINGLE NONSENSED COMPLEXES IN A CODEPENDENT CARDIOVERTER DEFIBRILLATOR AND BRADYCARDIA PACING SYSTEM - POTENTIAL FOR VENTRICULAR-TACHYCARDIA INDUCTION [J].
CALLANS, DJ ;
HOOK, BG ;
MARCHLINSKI, FE .
PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 1991, 14 (08) :1281-1287
[5]   EFFICACY OF AUTOMATIC MULTIMODAL DEVICE THERAPY FOR VENTRICULAR TACHYARRHYTHMIAS AS DELIVERED BY A NEW IMPLANTABLE PACING CARDIOVERTER-DEFIBRILLATOR - RESULTS OF A EUROPEAN MULTICENTER STUDY OF 102 IMPLANTS [J].
FROMER, M ;
BRACHMANN, J ;
BLOCK, M ;
SIEBELS, J ;
HOFFMANN, E ;
ALMENDRAL, J ;
OHM, OJ ;
DENDULK, K ;
COUMEL, P ;
CAMM, AJ ;
TOUBOUL, P .
CIRCULATION, 1992, 86 (02) :363-374
[6]   COMPLICATIONS OF IMPLANTABLE CARDIOVERTER DEFIBRILLATOR THERAPY - FOLLOW-UP OF 241 PATIENTS [J].
GRIMM, W ;
FLORES, BF ;
MARCHLINSKI, FE .
PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 1993, 16 (01) :218-222
[7]   ELECTROCARDIOGRAPHICALLY DOCUMENTED UNNECESSARY, SPONTANEOUS SHOCKS IN 241 PATIENTS WITH IMPLANTABLE CARDIOVERTER DEFIBRILLATORS [J].
GRIMM, W ;
FLORES, BF ;
MARCHLINSKI, FE .
PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 1992, 15 (11) :1667-1673
[8]   IMPORTANCE OF ABORTIVE SHOCK CAPABILITY WITH ELECTROGRAM STORAGE IN CARDIOVERTER-DEFIBRILLATOR DEVICES [J].
HURWITZ, JL ;
HOOK, BG ;
FLORES, BT ;
MARCHLINSKI, FE .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1993, 21 (04) :895-900
[9]   ARRHYTHMIAS INDUCED BY DEVICE ANTITACHYCARDIA THERAPY DUE TO DIAGNOSTIC NONSPECIFICITY [J].
JOHNSON, NJ ;
MARCHLINSKI, FE .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1991, 18 (05) :1418-1425
[10]  
JORDAENS L, 1993, BRIT HEART J, V69, P14