HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHIC DETERMINATION OF GUANIDINO COMPOUNDS BY AUTOMATED PRECOLUMN FLUORESCENCE DERIVATIZATION

被引:17
作者
BOPPANA, VK [1 ]
RHODES, GR [1 ]
机构
[1] SK&F LABS,DEPT DRUG METAB,POB 1539,KING OF PRUSSIA,PA 19406
来源
JOURNAL OF CHROMATOGRAPHY | 1990年 / 506卷
关键词
D O I
10.1016/S0021-9673(01)91584-5
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
An automated pre-column derivatization approach was used to develop an high-performance liquid chromatographic method for the determination of endogenous guanidino compounds. A commercially available autoinjector which was capable of adding and mixing reagent solutions and timing the reaction prior to injection was used to generate a fluorescent product by reaction of guanidino compounds with alkaline ninhydrin. The fluorescent products were separated by reversed-phase chromatography and detected with a fluorometer. Optimization of the pre-column reaction conditions resulted in a simple, highly sensitive and specific analytical method for the determination of guanidino compounds with excellent reproducibility and linearity. Application of this methodology to the determination of methylguanidine in human plasma samples resulted in a limit of quantification of 1 ng/ml (13.7 pmol/ml). The method was successfully employed for the quantification of circulating levels of methylguanidine in normal human subjects and uremic patients. The methodology should be generally applicable to the detection of other guanidino compounds in biological fluids. © 1990.
引用
收藏
页码:279 / 288
页数:10
相关论文
共 13 条
[1]   REVERSED-PHASE ION-PAIRING LIQUID-CHROMATOGRAPHIC SEPARATION AND FLUOROMETRIC DETECTION OF GUANIDINO COMPOUNDS [J].
BAKER, MD ;
MOHAMMED, HY ;
VEENING, H .
ANALYTICAL CHEMISTRY, 1981, 53 (11) :1658-1662
[2]  
BARSOTTI G, 1975, KIDNEY INT, V7, pS299
[3]   EVIDENCE THAT METHYLGUANIDINE IS RETAINED IN CHRONIC RENAL FAILURE [J].
GIOVANNE.S ;
BIAGINI, M ;
CIONI, L .
EXPERIENTIA, 1968, 24 (04) :341-&
[4]   METHYLGUANIDINE IN UREMIA [J].
GIOVANNETTI, S ;
BALESTRI, PL ;
BARSOTTI, G .
ARCHIVES OF INTERNAL MEDICINE, 1973, 131 (05) :709-713
[5]  
GIOVANNETTI S, 1969, CLIN SCI, V36, P445
[6]   POST-COLUMN DERIVATIZATION OF GUANIDINO COMPOUNDS IN HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY USING NINHYDRIN [J].
HIRAGA, Y ;
KINOSHITA, T .
JOURNAL OF CHROMATOGRAPHY, 1981, 226 (01) :43-51
[7]   HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHIC ANALYZER FOR GUANIDINO COMPOUNDS USING BENZOIN AS A FLUOROGENIC REAGENT [J].
HUNG, YL ;
KAI, M ;
NOHTA, H ;
OHKURA, Y .
JOURNAL OF CHROMATOGRAPHY, 1984, 305 (02) :281-294
[8]   HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY OF GUANIDINO COMPOUNDS USING BENZOIN AS A PRECOLUMN FLUORESCENT DERIVATIZATION REAGENT [J].
KAI, M ;
MIYAZAKI, T ;
YAMAGUCHI, M ;
OHKURA, Y .
JOURNAL OF CHROMATOGRAPHY, 1983, 268 (03) :417-424
[9]   HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHIC MEASUREMENT OF GUANIDINO COMPOUNDS OF CLINICAL IMPORTANCE IN HUMAN-URINE AND SERUM BY PRE-COLUMN FLUORESCENCE DERIVATIZATION USING BENZOIN [J].
KAI, M ;
MIYAZAKI, T ;
OHKURA, Y .
JOURNAL OF CHROMATOGRAPHY, 1984, 311 (02) :257-266
[10]   FLUOROMETRIC-DETERMINATION OF GUANIDINO COMPOUNDS BY NEW POSTCOLUMN DERIVATIZATION SYSTEM USING REVERSED-PHASE ION-PAIR HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY [J].
KOBAYASHI, Y ;
KUBO, H ;
KINOSHITA, T .
ANALYTICAL BIOCHEMISTRY, 1987, 160 (02) :392-398