CALIBRATION OF THE RUBY R(1) AND R(2) FLUORESCENCE SHIFTS AS A FUNCTION OF TEMPERATURE FROM 0 TO 600-K

被引:184
作者
RAGAN, DD
GUSTAVSEN, R
SCHIFERL, D
机构
[1] Los Alamos National Laboratory, Los Alamos
关键词
D O I
10.1063/1.351951
中图分类号
O59 [应用物理学];
学科分类号
摘要
Recent work by Gupta and Shen [Appl. Phys Lett. 58, 583 (1991)] has shown that in a nonhydrostatic environment, the frequency of the ruby R2 line provides a reliable measure of the mean stress or pressure. When using the frequency of either the R1 or R2 line to measure pressure at nonambient temperature, it is necessary to know the temperature dependence of the line shift. Unfortunately, the shift of the R2 line with temperature has not been reported. The ruby R1 and R2 fluorescence shifts have been determined as a function of temperature from 15 to 600 K. Both can be fitted very well to the simple cubic forms R1(T) = 14 423 + 4.49 x 10(-2) T - 4.81 x 10(-4) T2 + 3.71 x 10(-7) T3 cm-1 and R2(T) = 14 452 + 3.00 x 10(-2) T - 3.88 x 10(-4) T2 + 2.55 x 10(-7) T3 cm-1. From 300 to 600 K the shifts fit well to linear functions of temperature. In addition, it is found that the R1-R2 Splitting changes by about 3 cm-1 over the 600 K temperature range. Linewidths were found to vary both with temperature and from sample to sample.
引用
收藏
页码:5539 / 5544
页数:6
相关论文
共 27 条
[1]   SPECTROSCOPY AT VERY HIGH-PRESSURES .10. USE OF RUBY R-LINES IN ESTIMATION OF PRESSURE AT AMBIENT AND AT LOW-TEMPERATURES [J].
ADAMS, DM ;
APPLEBY, R ;
SHARMA, SK .
JOURNAL OF PHYSICS E-SCIENTIFIC INSTRUMENTS, 1976, 9 (12) :1140-1144
[2]  
[Anonymous], 1969, DATA REDUCTION ERROR
[3]   OPTICAL FLUORESCENCE SYSTEM FOR QUANTITATIVE PRESSURE MEASUREMENT IN DIAMOND-ANVIL CELL [J].
BARNETT, JD ;
BLOCK, S ;
PIERMARINI, GJ .
REVIEW OF SCIENTIFIC INSTRUMENTS, 1973, 44 (01) :1-9
[4]  
BELL PM, 1985, SHOCK WAVES CONDENSE, P125
[5]  
BRISTER K, COMMUNICATION
[6]   PHASE-DIAGRAM OF N2 DETERMINED BY RAMAN-SPECTROSCOPY FROM 15 TO 300 K AT PRESSURES TO 52 GPA [J].
BUCHSBAUM, S ;
MILLS, RL ;
SCHIFERL, D .
JOURNAL OF PHYSICAL CHEMISTRY, 1984, 88 (12) :2522-2525
[7]  
BURT JA, 1989, THESIS WASHINGTON ST
[8]  
DEVORE JL, 1982, PROBABILITY STATISTI, P455
[9]   PRESSURE MEASUREMENT MADE BY UTILIZATION OF RUBY SHARP-LINE LUMINESCENCE [J].
FORMAN, RA ;
BLOCK, S ;
BARNETT, JD ;
PIERMARINI, GJ .
SCIENCE, 1972, 176 (4032) :284-+
[10]   POTENTIAL USE OF THE RUBY R2 LINE SHIFT FOR STATIC HIGH-PRESSURE CALIBRATION [J].
GUPTA, YM ;
SHEN, XA .
APPLIED PHYSICS LETTERS, 1991, 58 (06) :583-585