AUTOMATIC ALIGNMENT-CONTROL SYSTEM FOR A SUSPENDED FABRY-PEROT CAVITY

被引:10
作者
KAWABE, K
MIO, N
TSUBONO, K
机构
[1] Department of Physics, University of Tokyo, Tokyo, 113, 7-3-1 Hongo, Bunkyo-ku
来源
APPLIED OPTICS | 1994年 / 33卷 / 24期
关键词
GRAVITATIONAL-WAVE DETECTORS; FABRY-PEROT CAVITY; ALIGNMENT CONTROL;
D O I
10.1364/AO.33.005498
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
In interferometric gravitational-wave detectors, most of the optical components are suspended by wires so that they are isolated from all kinds of forces except gravity. The requirement for the alignment of optical components to the laser beam is crucial. We have demonstrated a servo system developed for a Fabry-Perot cavity whose mirrors are suspended independently. We use mechanical modulation and a lock-in detection method to detect any misalignment. This system directly detects the relation between the axis of the laser beam and the axis of the cavity and automatically aligns the cavity to the laser beam. We confirmed that the intensity of the reflected light from the suspended Fabry-Perot cavity can be minimized with this system. Automated control of the alignment of the large-scale detectors is also discussed.
引用
收藏
页码:5498 / 5505
页数:8
相关论文
共 11 条
[1]  
ANDERSON DZ, 1984, APPL OPTICS, V23, P2944, DOI 10.1364/AO.23.002944
[2]  
BARONE F, 1989, 8TH P IT C GEN REL G, P551
[3]   LASER PHASE AND FREQUENCY STABILIZATION USING AN OPTICAL-RESONATOR [J].
DREVER, RWP ;
HALL, JL ;
KOWALSKI, FV ;
HOUGH, J ;
FORD, GM ;
MUNLEY, AJ ;
WARD, H .
APPLIED PHYSICS B-PHOTOPHYSICS AND LASER CHEMISTRY, 1983, 31 (02) :97-105
[4]   WIDEBAND LASER-INTERFEROMETER GRAVITATIONAL-RADIATION EXPERIMENT [J].
FORWARD, RL .
PHYSICAL REVIEW D, 1978, 17 (02) :379-390
[5]   INTERFEROMETRIC DETECTION OF GRAVITATIONAL-WAVES [J].
GIAZOTTO, A .
PHYSICS REPORTS-REVIEW SECTION OF PHYSICS LETTERS, 1989, 182 (06) :365-424
[6]  
KAWAMURA S, 1992, 6TH P M GROSSM M GEN, P1486
[7]   WAVE-FRONT DISTORTION IN LASER-INTERFEROMETRIC GRAVITATIONAL-WAVE DETECTORS [J].
MEERS, BJ ;
STRAIN, KA .
PHYSICAL REVIEW D, 1991, 43 (10) :3117-3130
[8]   SHORT-TERM AND LONG-TERM FREQUENCY STABILIZATION OF A HE-NE-LASER USING A FABRY-PEROT CAVITY LOCKED TO THE LAMB DIP [J].
MIO, N ;
TSUBONO, K .
APPLIED PHYSICS B-PHOTOPHYSICS AND LASER CHEMISTRY, 1992, 54 (03) :202-204
[9]   STABILIZATION OF LASER-BEAM ALIGNMENT TO AN OPTICAL-RESONATOR BY HETERODYNE-DETECTION OF OFF-AXIS MODES [J].
SAMPAS, NM ;
ANDERSON, DZ .
APPLIED OPTICS, 1990, 29 (03) :394-403
[10]   NOISE BEHAVIOR OF THE GARCHING 30-METER PROTOTYPE GRAVITATIONAL-WAVE DETECTOR [J].
SHOEMAKER, D ;
SCHILLING, R ;
SCHNUPP, L ;
WINKLER, W ;
MAISCHBERGER, K ;
RUDIGER, A .
PHYSICAL REVIEW D, 1988, 38 (02) :423-432