PHOTON ENERGY-DEPENDENCE OF THE SENSITIVITY OF RADIOCHROMIC FILM AND COMPARISON WITH SILVER-HALIDE FILM AND LIF TLDS USED FOR BRACHYTHERAPY DOSIMETRY

被引:163
作者
MUENCH, PJ [1 ]
MEIGOONI, AS [1 ]
NATH, R [1 ]
MCLAUGHLIN, WL [1 ]
机构
[1] NATL INST STAND & TECHNOL,CTR RADIAT RES,GAITHERSBURG,MD 20899
关键词
RADIOCHROMIC FILM; BRACHYTHERAPY; DOSE-DISTRIBUTION MAPPING; ENERGY DEPENDENCE; DOSIMETRY;
D O I
10.1118/1.596630
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
There is a new radiochromic film, a highly uniform, thin (100-mu-m) detector whose sensitive layer (6-mu-m thick) changes from colorless to blue by dye polymerization without processing, upon exposure to ionizing radiation. Because the dose gradients around brachytherapy sources are steep, the high spatial resolution offered by film dosimetry is an advantage over other detectors such as thermoluminescent dosimeters (TLDs). This compares the photon energy dependence of the sensitivities of GafChromic film, silver halide verification film (Kodak X-Omat V Film), and lithium fluoride TLDs (Harshaw), over the photon energy range 28 keV to 1.7 MeV, which is of interest in brachytherapy. Sensitivity of the radiochromic film is observed to decrease by about 30% as effective photon energy decreases from 1710 keV (4-MV x rays) to 28 keV (60-kV x rays, 2-mm Al filter). In contrast, the sensitivity of verification film increases by 980% and that of LiF TLDs increases by 41%. The variation of the sensitivity of radiochromic film with photon energy is considerably less than that for silver halide film and similar to that for LiF TLDs, but in the opposite direction. Radiochromic film, like LIF TLDs, does not exhibit the drastic sensitivity changes below 127 keV that silver halide film exhibits. Dose distribution in the immediate vicinity of a high activity (370 GBq) brachytherapy Ir-192 source has been mapped using radiochromic film and is presented to illustrate the applicability of this new technology to brachytherapy dosimetry.
引用
收藏
页码:769 / 775
页数:7
相关论文
共 11 条
[1]  
CERRA F, 1990, ENDOCUR HYPERTHER ON, V6, P71
[2]  
CHU RDH, 1990, RADIAT PHYS CHEM, V35, P767
[3]  
JOHNS H, 1983, PHYS RADIOLOGY, P732
[4]  
LEWIS DF, COMMUNICATION
[5]   SENSITOMETRY OF THE RESPONSE OF A NEW RADIOCHROMIC FILM DOSIMETER TO GAMMA-RADIATION AND ELECTRON-BEAMS [J].
MCLAUGHLIN, WL ;
YUNDONG, C ;
SOARES, CG ;
MILLER, A ;
VANDYK, G ;
LEWIS, DF .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1991, 302 (01) :165-176
[6]  
MCLAUGHLIN WL, 1985, IAEA STTPUB691 PUBL, P397
[7]   INFLUENCE OF THE VARIATION OF ENERGY-SPECTRA WITH DEPTH IN THE DOSIMETRY OF IR-192 USING LIF TLD [J].
MEIGOONI, AS ;
MELI, JA ;
NATH, R .
PHYSICS IN MEDICINE AND BIOLOGY, 1988, 33 (10) :1159-1170
[8]  
PLECHATY EF, 1975, UCRL504006 LAWR LIV
[9]  
SAYLOR MC, 1988, RADIAT PHYS CHEM, V31, P529
[10]  
TARGOVNIK H, 1990, COMMUNICATION APR