FLOW-INJECTION SPECTROPHOTOMETRIC DETERMINATION OF CYCLAMATE IN LOW-CALORIE SOFT DRINKS AND SWEETENERS

被引:22
作者
GOUVEIA, ST
FATIBELLO, O
NOBREGA, JD
机构
[1] UNIV FED SAO CARLOS,DEPT QUIM,QUIM ANALIT GRP,BR-13560905 SAO CARLOS,SP,BRAZIL
[2] UNIV SAO PAULO,INST QUIM SAO CARLOS,BR-13560970 SAO CARLOS,SP,BRAZIL
关键词
CYCLAMATE DETERMINATION; DIET PRODUCT; LOW CALORIE SWEETENER; FLOW INJECTION SPECTROPHOTOMETRY; GRIESS REACTION;
D O I
10.1039/an9952002009
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A flow injection spectrophotometric procedure is proposed for the determination of cyclamate in low calorie soft drinks and sweeteners. The system is based on the reaction between nitrite and cyclamate in a medium containing 0.1 mol l(-1) phosphoric acid; the excess of reducing agent is determined by the Griess reaction. The flow system is designed to provide a residence time compatible with the rate of the redox process. To eliminate interference caused by dye additives an alumina column is used. During the sampling stage, the dyes are removed and the loop, positioned in series, becomes filled with the colourless sample solution. After sample injection, the alumina column is regenerated by an alkaline solution flowing in the opposite direction. Cyclamate was determined in nine diet products. Some results were compared with those obtained by a bi-amperometric procedure (correlation coefficient, r = 0.9999, n = 4) and others were compared with label values (r = 0.9965, n = 5). The detection limit was 3.0 x 10(-5) mol l(-1) and the relative standard deviation was less than 0.5% for a solution containing 8.0 x 10(-4) mol l(-1) of cyclamate (n = 12). The proposed system allowed us to obtain 24 results h(-1) and this was limited by the on-line adsorption of dyes on the alumina column.
引用
收藏
页码:2009 / 2012
页数:4
相关论文
共 19 条
[1]  
BIEMER TA, 1989, J CHROMATOGR, V463, P563
[2]   DETERMINATION OF CYCLAMATE IN SOFT DRINKS BY REACTION WITH NITROUS ACID - GAS - LIQUID CHROMATOGRAPHIC DETERMINATION OF CYCLOHEXENE AND OF CYCLOHEXYL NITRITE [J].
DALZIEL, JAW ;
JOHNSON, RM ;
SHENTON, AJ .
ANALYST, 1972, 97 (1158) :719-&
[3]   FLOW-INJECTION POTENTIOMETRIC DETERMINATION OF SACCHARIN IN DIETARY PRODUCTS WITH RELOCATION OF FILTRATION UNIT [J].
FATIBELLO-FILHO, O ;
NOBREGA, JA ;
GUARITASANTOS, AJM .
TALANTA, 1994, 41 (05) :731-734
[4]  
FATIBELLOFILHO O, UNPUB
[5]  
FOX JB, 1985, CRC CR REV ANAL CHEM, V15, P283
[6]  
HOWARD JW, 1969, J ASSOC OFF ANA CHEM, V52, P492
[7]  
KARLBERG B, 1989, FLOW INJECTION ANAL, P3
[8]  
KURAYUKI Y, 1966, ANAL ABSTR, V15, P1064
[9]  
LOPEZ GI, 1968, ANAL CIENC, V45, P25
[10]  