MEASUREMENT OF BLOOD-FLOW THROUGH AV-FISTULAS BY MEANS OF DOPPLER SONOGRAPHY IN REGULARLY HEMODIALYZED PATIENTS

被引:9
作者
KRPAN, D
DEMARIN, V
PROT, F
MILUTINOVIC, S
MOLNAR, V
MILUTINOVIC, E
机构
[1] UNIV ZAGREB, DR J KAIFES GEN HOSP, CTR HAEMODIALYSIS & NEPHROL, YU-41001 Zagreb, YUGOSLAVIA
[2] UNIV ZAGREB, DR MLADEN STOJANOVIC UNIV HOSP, YU-41001 Zagreb, YUGOSLAVIA
[3] UNIV ZAGREB, FAC PHYS CULTURE, INST KINESIOL, YU-41001 Zagreb, YUGOSLAVIA
关键词
DOPPLER ULTRASOUND; HEMODIALYSIS; BLOOD FLOW; ARTERIOVENOUS FISTULA;
D O I
10.1177/039139889101400204
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
In regularly dialyzed patients a variety of pathological events can negatively influence haemodynamics and blood flow through arterio-venous fistula, leading to inadequate blood flow through the dialyzer or disturbances in hemodynamics of the whole body. It therefore appears important to quantify flow velocity and volume flow through the arteriovenous fistula in such cases. We used a Vasoview computer controlled system for noninvasive vascular diagnostics based on B-scan "real-time" ultrasound for imaging the structure of tissue, combined with pulsed Doppler ultrasound for determination of hemodynamics. Thirty patients (16 males and 14 females, aged 45 +/- 10 years; range 23 to 61 years), with different periods spent on hemodialysis (5.5 +/- 3.1 years, range 1 to 11 years) were included in this study. The average systolic, diastolic and mean blood volume flows were 2131.8 +/- 565.8, 972.0 +/- 309.6 and 728.4 +/- 287.4 ml/min, respectively. The mean blood volume flow was calculated by integration of the area under curve of blood flow in one heart cycle on the Doppler signal. It is calculated by the apparatus and displayed on the screen during measurement. The average blood vessel diameter was 9.1 +/- 1.3 mm (mu +/- sigma). The results revealed a marked inter-individual variation in volume flow through arteriovenous fistulae of dialyzed uremics (range 240.0 to 1200.0 ml/min). Doppler ultrasound thus appears to be a valuable method for determination of blood flow through arteriovenous fistula of dialyzed uremics as well as for detection of hemodynamics disturbances of interest, such as turbulent blood flow.
引用
收藏
页码:78 / 82
页数:5
相关论文
共 14 条
  • [1] ANCARANI G, 1982, INT C ACCESS SURGERY, P39
  • [2] CAROTID-ARTERY VELOCITY PATTERNS IN NORMAL AND STENOTIC VESSELS
    BLACKSHEAR, WM
    PHILLIPS, DJ
    CHIKOS, PM
    HARLEY, JD
    THIELE, BL
    STRANDNESS, DE
    [J]. STROKE, 1980, 11 (01) : 67 - 71
  • [3] Boskovic S, 1984, Acta Chir Iugosl, V31, P17
  • [4] QUANTITATIVE DOPPLER AND ULTRASOUND MEASUREMENTS IN SURGICALLY PERFORMED ARTERIOVENOUS-FISTULAS OF THE ARM
    FORSBERG, L
    HOLMIN, T
    LINDSTEDT, E
    [J]. ACTA RADIOLOGICA-DIAGNOSIS, 1980, 21 (06): : 769 - 776
  • [5] HART A, 1981, T AM SOC ART INT ORG, V27, P623
  • [6] HODAKDEMARIN V, 1981, PROGR MED ULTRASOUND, V2, P239
  • [7] TRANS-CUTANEOUS QUANTITATION OF ARTERIAL FLOW WITH ULTRASOUND
    KASULKE, RJ
    LICHTI, EA
    KAPSCH, DN
    SILVER, D
    [J]. ANNALS OF SURGERY, 1982, 195 (04) : 464 - 468
  • [8] KEITZER WF, 1975, ANGIOLOGY, V26, P172
  • [9] MILLER JH, 1984, T AM SOC ART INT ORG, V30, P377
  • [10] FLOW OF DIALYSIS FISTULAS - NONINVASIVE STUDY PERFORMED WITH STANDARD DOPPLER EQUIPMENT
    MORAN, MR
    RODRIGUEZ, JMR
    BOYERO, MR
    ENRIQUEZ, AA
    MORIN, AI
    [J]. NEPHRON, 1985, 40 (01): : 63 - 66