COMPARISON OF REVERSED-POLARITY CAPILLARY ELECTROPHORESIS AND ADSORPTIVE STRIPPING VOLTAMMETRY FOR THE DETECTION AND DETERMINATION OF REACTIVE TEXTILE DYES

被引:11
作者
OXSPRING, DA [1 ]
SMYTH, WF [1 ]
MARCHANT, R [1 ]
机构
[1] UNIV ULSTER,DEPT APPL BIOL & CHEM SCI,COLERAINE BT52 1SA,LONDONDERRY,NORTH IRELAND
关键词
REVERSED-POLARITY CAPILLARY ELECTROPHORESIS; ADSORPTIVE STRIPPING VOLTAMMETRY; REACTIVE TEXTILE DYE; HYDROLYZED DYE;
D O I
10.1039/an9952001995
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Reversed-polarity capillary electrophoresis (CE) and adsorptive stripping voltammetry (AdSV) using a hanging mercury drop electrode are compared for the separation and determination of six reactive textile dyes, Only four of the six starting dyes could be separated in the reversed-polarity mode of CE. No change in pH, temperature, run buffer, acetonitrile concentration or surfactant brought about separation of all six dyes. Optimum separation of the hydrolysed dyes was achieved using an electrolyte of 0.05 mol dm(-3) citric acid (pH 3.25) with 10% acetonitrile. Stacking of the dyes was performed using a 0.05 mol dm(-3) citric acid buffer (pH 2.23), containing 0.006 mol dm(-3) diethylenetriamine. Electrokinetic injections were investigated using 0.05 mol dm(-3) citric acid (pH 2.23) buffer with an injection time of 30 s at a voltage of 10 kV. AdSV studies were carried out using a 0.2 mol dm(-3) acetate-acetic acid buffer (pH 4.5) and a 5 min accumulation time at the mercury electrode. The correlation coefficients of the calibration graphs and limits of detection for both techniques are also compared.
引用
收藏
页码:1995 / 2000
页数:6
相关论文
共 19 条
[1]   LARGE-VOLUME STACKING OF ANIONS IN CAPILLARY ELECTROPHORESIS USING AN ELECTROOSMOTIC FLOW MODIFIER AS A PUMP [J].
BURGI, DS .
ANALYTICAL CHEMISTRY, 1993, 65 (24) :3726-3729
[2]  
BURGI DS, 1992, ANAL BIOCHEM, V16, P2161
[3]   THE EFFECT OF INJECTION PROCEDURES ON EFFICIENCY IN MICELLAR ELECTROKINETIC CAPILLARY CHROMATOGRAPHY [J].
BURTON, DE ;
SEPANIAK, MJ ;
MASKARINEC, MP .
CHROMATOGRAPHIA, 1986, 21 (10) :583-586
[4]  
CAMILLERI P, 1993, CAPILLARY ELECTROPHO
[5]   FIELD-AMPLIFIED POLARITY-SWITCHING SAMPLE INJECTION IN HIGH-PERFORMANCE CAPILLARY ELECTROPHORESIS [J].
CHIEN, RL ;
BURGI, DS .
JOURNAL OF CHROMATOGRAPHY, 1991, 559 (1-2) :153-161
[6]   ANALYSIS OF REACTIVE DYES AND RELATED DERIVATIVES USING HIGH-PERFORMANCE CAPILLARY ELECTROPHORESIS [J].
CROFT, SN ;
LEWIS, DM .
DYES AND PIGMENTS, 1992, 18 (04) :309-317
[7]  
CROFT SN, 1993, TEXT CHEM COLOR, V25, P47
[8]   USE OF DERIVATIZATION REACTIONS WITH ADSORPTIVE STRIPPING VOLTAMMETRY - DIAZOTIZATION AND COUPLING OF AROMATIC-AMINES [J].
FOGG, AG ;
LEWIS, JM .
ANALYST, 1986, 111 (12) :1443-1444
[9]  
GOODALL DM, 1993, SHORT COURSE CAPILLA
[10]   SEPARATION OF PYRIDINECARBOXYLIC ACID ISOMERS AND RELATED-COMPOUNDS BY CAPILLARY ZONE ELECTROPHORESIS - EFFECT OF CETYLTRIMETHYLAMMONIUM BROMIDE ON ELECTROOSMOTIC FLOW AND RESOLUTION [J].
JANINI, GM ;
CHAN, KC ;
BARNES, JA ;
MUSCHIK, GM ;
ISSAQ, HJ .
JOURNAL OF CHROMATOGRAPHY A, 1993, 653 (02) :321-327