ACCURACY OF AUTOMATICALLY DETERMINED BORDERS IN DIGITAL TWO-DIMENSIONAL ECHOCARDIOGRAPHY USING A CARDIAC PHANTOM

被引:12
作者
WOLFE, ER
DELP, EJ
MEYER, CR
BOOKSTEIN, FL
BUDA, AJ
机构
[1] PURDUE UNIV,SCH ELECT ENGN,W LAFAYETTE,IN 47907
[2] UNIV MICHIGAN,SCH MED,DEPT RADIOL,ANN ARBOR,MI 48109
[3] UNIV MICHIGAN,CTR HUMAN GROWTH & DEV,ANN ARBOR,MI 48109
关键词
D O I
10.1109/TMI.1987.4307845
中图分类号
TP39 [计算机的应用];
学科分类号
081203 ; 0835 ;
摘要
引用
收藏
页码:292 / 296
页数:5
相关论文
共 20 条
[1]  
BOOKSTEIN FL, 1978, LECTURE NOTES BIOMAT, V24
[2]   AUTOMATIC COMPUTER-PROCESSING OF DIGITAL TWO-DIMENSIONAL ECHOCARDIOGRAMS [J].
BUDA, AJ ;
DELP, EJ ;
MEYER, CR ;
JENKINS, JM ;
SMITH, DN ;
BOOKSTEIN, FL ;
PITT, B .
AMERICAN JOURNAL OF CARDIOLOGY, 1983, 52 (03) :384-389
[3]   COMPUTER-ASSISTED EDGE-DETECTION IN TWO-DIMENSIONAL ECHOCARDIOGRAPHY - COMPARISON WITH ANATOMIC DATA [J].
COLLINS, SM ;
SKORTON, DJ ;
GEISER, EA ;
NICHOLS, JA ;
CONETTA, DA ;
PANDIAN, NG ;
KERBER, RE .
AMERICAN JOURNAL OF CARDIOLOGY, 1984, 53 (09) :1380-1387
[4]   ACCURATE VOLUME DETERMINATION IN THE ISOLATED EJECTING CANINE LEFT-VENTRICLE BY 2-DIMENSIONAL ECHOCARDIOGRAPHY [J].
EATON, LW ;
MAUGHAN, WL ;
SHOUKAS, AA ;
WEISS, JL .
CIRCULATION, 1979, 60 (02) :320-326
[5]   ASSESSMENT OF LEFT-VENTRICULAR EJECTION FRACTION AND VOLUMES BY REAL-TIME, 2-DIMENSIONAL ECHOCARDIOGRAPHY - COMPARISON OF CINEANGIOGRAPHIC AND RADIONUCLIDE TECHNIQUES [J].
FOLLAND, ED ;
PARISI, AF ;
MOYNIHAN, PF ;
JONES, DR ;
FELDMAN, CL ;
TOW, DE .
CIRCULATION, 1979, 60 (04) :760-766
[6]   REAL-TIME COMPUTERIZATION OF TWO-DIMENSIONAL ECHOCARDIOGRAPHY [J].
GARCIA, E ;
GUERET, P ;
BENNETT, M ;
CORDAY, E ;
ZWEHL, W ;
MEERBAUM, S ;
CORDAY, S ;
SWAN, HJC ;
BERMAN, D .
AMERICAN HEART JOURNAL, 1981, 101 (06) :783-792
[7]   QUANTIFICATION OF LEFT-VENTRICULAR FUNCTION BY TWO-DIMENSIONAL ECHOCARDIOGRAPHY - CONSIDERATION OF FACTORS RESTRICTING IMAGE QUALITY [J].
GEISER, EA ;
SKORTON, DJ ;
CONETTA, DA .
AMERICAN HEART JOURNAL, 1982, 103 (05) :905-910
[8]   TWO-DIMENSIONAL ECHOCARDIOGRAPHIC ASSESSMENT OF LEFT-VENTRICULAR STROKE VOLUME - EXPERIMENTAL CORRELATION WITH THERMODILUTION AND CINEANGIOGRAPHY IN NORMAL AND ISCHEMIC STATES [J].
GUERET, P ;
MEERBAUM, S ;
ZWEHL, W ;
WYATT, HL ;
DAVIDSON, RM ;
UCHIYAMA, T ;
CORDAY, E .
CATHETERIZATION AND CARDIOVASCULAR DIAGNOSIS, 1981, 7 (03) :247-258
[9]   DIGITAL STEP EDGES FROM ZERO CROSSING OF 2ND DIRECTIONAL-DERIVATIVES [J].
HARALICK, RM .
IEEE TRANSACTIONS ON PATTERN ANALYSIS AND MACHINE INTELLIGENCE, 1984, 6 (01) :58-68
[10]   QUANTITATION OF HUMAN LEFT-VENTRICULAR MASS - AND VOLUME BY TWO-DIMENSIONAL ECHOCARDIOGRAPHY - INVITRO ANATOMIC VALIDATION [J].
HELAK, JW ;
REICHEK, N .
CIRCULATION, 1981, 63 (06) :1398-1407