LINEAR DIMENSION REDUCTION OF SEQUENCES OF MEDICAL IMAGES .2. DIRECT SUM DECOMPOSITION

被引:16
作者
HERMANSEN, F [1 ]
BLOOMFIELD, PM [1 ]
ASHBURNER, J [1 ]
CAMICI, PG [1 ]
LAMMERTSMA, AA [1 ]
机构
[1] HAMMERSMITH HOSP,ROYAL POSTGRAD MED SCH,MRC,CTR CLIN SCI,CYCLOTRON UNIT,PET,CARDIOL GRP,LONDON W12 0HS,ENGLAND
关键词
D O I
10.1088/0031-9155/40/11/011
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Using unitary transformations together with a previously described statistical theory for optimal linear dimension reduction it is shown how pixels in a sequence of images can be decomposed into a sum of variates, covariates, and residual vectors, with all covariances equal to zero. It is demonstrated that this decomposition is optimal with respect to noise. In addition, it results in simplified and well conditioned equations for dimension reduction and elimination of covariates. The factor images are not degraded by subdivision of the time intervals. In contrast to traditional factor analysis, the factors can be measured directly or calculated based on physiological models. This procedure not only solves the rotation problem associated with factor analysis, but also eliminates the need for calculation of the principal components altogether. Examples are given of factor images of the heart, generated from a dynamic study using oxygen-15-labelled water and positron emission tomography. As a special application of the method, it is shown that the factor images may reveal any contamination of the blood curve derived from the original dynamic images with myocardial activity.
引用
收藏
页码:1921 / 1941
页数:21
相关论文
共 17 条
[1]  
Altman P. L., 1971, RESPIRATION CIRCULAT
[2]  
[Anonymous], 2003, MULTIVARIATE STAT AN
[3]   NONINVASIVE QUANTIFICATION OF REGIONAL MYOCARDIAL BLOOD-FLOW IN CORONARY-ARTERY DISEASE WITH OXYGEN-15-LABELED CARBON-DIOXIDE INHALATION AND POSITRON EMISSION TOMOGRAPHY [J].
ARAUJO, LI ;
LAMMERTSMA, AA ;
RHODES, CG ;
MCFALLS, EO ;
IIDA, H ;
RECHAVIA, E ;
GALASSI, A ;
DESILVA, R ;
JONES, T ;
MASERI, A .
CIRCULATION, 1991, 83 (03) :875-885
[4]  
Golub G.H., 1996, MATH GAZ, VThird
[5]   LINEAR DIMENSION REDUCTION OF SEQUENCES OF MEDICAL IMAGES .1. OPTIMAL INNER PRODUCTS [J].
HERMANSEN, F ;
LAMMERTSMA, AA .
PHYSICS IN MEDICINE AND BIOLOGY, 1995, 40 (11) :1909-1920
[6]   PET SYSTEM CALIBRATIONS AND CORRECTIONS FOR QUANTITATIVE AND SPATIALLY ACCURATE IMAGES [J].
HOFFMAN, EJ ;
GUERRERO, TM ;
GERMANO, G ;
DIGBY, WM ;
DAHLBOM, M .
IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1989, 36 (01) :1108-1112
[7]  
HOFFMAN EJ, 1984, ANN NEUROL, V15, pS25
[8]  
IIDA H, 1989, IEEE T NUCL SCI, V37, P1006
[9]   MEASUREMENT OF REGIONAL MYOCARDIAL BLOOD-FLOW USING C15O2 AND POSITRON EMISSION TOMOGRAPHY - COMPARISON OF TRACER MODELS [J].
LAMMERTSMA, AA ;
DESILVA, R ;
ARAUJO, LI ;
JONES, T .
CLINICAL PHYSICS AND PHYSIOLOGICAL MEASUREMENT, 1992, 13 (01) :1-20
[10]  
Lawson C. J., 1974, SOLVING LEAST SQUARE