LC-MS FOR TOXICOLOGICAL AND ENVIRONMENTAL-ANALYSIS - RECENT DEVELOPMENTS

被引:15
作者
LINSCHEID, M [1 ]
机构
[1] ISAS, W-4600 DORTMUND 1, GERMANY
关键词
LIQUID-CHROMATOGRAPHY MASS-SPECTROMETRY; ENVIRONMENTAL ANALYSIS; SPECIATION;
D O I
10.1080/03067319208028122
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The coupling of liquid chromatography and electrophoretic separation techniques with mass spectrometry has attracted great interest in almost all areas of analytical chemistry, because it holds many promises. Some interface types are used in routine analysis already, although GC-MS is often more sensitive and more reliable. The foremost benefit of using LC-MS is that the identification and determination of substances is possible, which were intractable with mass spectrometry, such as sulfonates, glucuronides, salts and metal organic species. New insights in metabolism of hazardous materials and new strategies for risk assessment are possible. In this report, an overview over the state of the art in the interface technique and some recent developments is given and, with a few selected examples (e.g detection of highly polar herbicides, metabolic analysis and speciation), the strength of LC-MS in environmental analysis shall be highlighted.
引用
收藏
页码:1 / 14
页数:14
相关论文
共 61 条
[1]   QUANTITATION AND LINEARITY FOR PARTICLE-BEAM LIQUID-CHROMATOGRAPHY MASS-SPECTROMETRY [J].
APFFEL, A ;
PERRY, ML .
JOURNAL OF CHROMATOGRAPHY, 1991, 554 (1-2) :103-118
[2]   GAS-NEBULIZED DIRECT LIQUID INTRODUCTION INTERFACE FOR LIQUID-CHROMATOGRAPHY MASS-SPECTROMETRY [J].
APFFEL, JA ;
BRINKMAN, UAT ;
FREI, RW ;
EVERS, EAIM .
ANALYTICAL CHEMISTRY, 1983, 55 (14) :2280-2284
[3]  
BLAKLEY CR, 1980, CLIN CHEM, V26, P1467
[4]   IDENTIFICATION OF TRIMETHYLLEAD IN URINE BY HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY WITH COLUMN SWITCHING AND CHEMICAL-REACTION DETECTION AND BY LIQUID-CHROMATOGRAPHY MASS-SPECTROMETRY [J].
BLASZKEWICZ, M ;
BAUMHOER, G ;
NEIDHART, B ;
OHLENDORF, R ;
LINSCHEID, M .
JOURNAL OF CHROMATOGRAPHY, 1988, 439 (01) :109-119
[5]  
BROWN MA, 1990, ACS SYM SER, P199
[6]  
BUSCH K L, 1989, Journal of Planar Chromatography - Modern TLC, V2, P355
[7]   HIGH-SENSITIVITY MASS-SPECTROMETRIC DETERMINATION OF PEPTIDES - DIRECT ANALYSIS OF AQUEOUS-SOLUTIONS [J].
CAPRIOLI, RM ;
FAN, T .
BIOCHEMICAL AND BIOPHYSICAL RESEARCH COMMUNICATIONS, 1986, 141 (03) :1058-1065
[8]   COUPLING CAPILLARY ZONE ELECTROPHORESIS AND CONTINUOUS-FLOW FAST ATOM BOMBARDMENT MASS-SPECTROMETRY FOR THE ANALYSIS OF PEPTIDE MIXTURES [J].
CAPRIOLI, RM ;
MOORE, WT ;
MARTIN, M ;
DAGUE, BB ;
WILSON, K ;
MORING, S .
JOURNAL OF CHROMATOGRAPHY, 1989, 480 :247-257
[9]  
COTTER RJ, 1986, IYO MASU KENKYUKAI K, V11, P21
[10]   COMPARISON OF THERMOSPRAY AND ION SPRAY MASS-SPECTROMETRY IN AN ATMOSPHERIC-PRESSURE ION-SOURCE [J].
COVEY, TR ;
BRUINS, AP ;
HENION, JD .
ORGANIC MASS SPECTROMETRY, 1988, 23 (03) :178-186