LASER-DOPPLER FLOWMETRY - A REVIEW OF ITS APPLICATION FOR MEASURING CEREBRAL AND SPINAL-CORD BLOOD-FLOW

被引:51
作者
FRERICHS, KU [1 ]
FEUERSTEIN, GZ [1 ]
机构
[1] SKF IND INC,RES & DEV,DEPT PHARMACOL,KING OF PRUSSIA,PA 19406
关键词
CBF; cerebral ischemia; laser; Laser-Doppler flowmetry; neuroinjury;
D O I
10.1007/BF03160057
中图分类号
Q189 [神经科学];
学科分类号
071006 ;
摘要
Laser-Doppler flowmetry is a new technique for noninvasive and continuous measurement of local microcirculatory cerebral and spinal-cord blood flow. The flow estimate by this technique is based on the assessment of the Doppler shift of low-power laser light, which is scattered by moving red blood cells. Laser-Doppler flowmetry has been validated for various organs, including the central nervous system. These studies revealed a linear relationship between relative changes of the Doppler signal and blood flow over a wide range of pharmacological as well as pathological flow alterations, including cerebral ischemia. The usefulness of laser-Doppler flowmetry in experimental as well as clinical applications has received growing attention. The superiority of the technique lies in its high spatial and temporal resolution. Disadvantages are the difficulty of obtaining absolute flow values and the sensitivity to artifacts. The versatility and on-line capacity of laser-Doppler flowmetry might allow new insights into the pathophysiology of alterations of the cerebral and spinal-cord microcirculation. © 1990 Humana Press Inc.
引用
收藏
页码:55 / 70
页数:16
相关论文
共 29 条
[1]   EVALUATION OF LASER DOPPLER FLOWMETRY IN THE ASSESSMENT OF INTESTINAL BLOOD-FLOW IN CAT [J].
AHN, H ;
LINDHAGEN, J ;
NILSSON, GE ;
SALERUD, EG ;
JODAL, M ;
LUNDGREN, O .
GASTROENTEROLOGY, 1985, 88 (04) :951-957
[2]   INTRAOPERATIVE MEASUREMENT OF CEREBRAL AND TUMOR BLOOD-FLOW WITH LASER-DOPPLER FLOWMETRY [J].
ARBIT, E ;
DIRESTA, GR ;
BEDFORD, RF ;
SHAH, NK ;
GALICICH, JH .
NEUROSURGERY, 1989, 24 (02) :166-170
[3]   MODEL FOR LASER DOPPLER MEASUREMENTS OF BLOOD-FLOW IN TISSUE [J].
BONNER, R ;
NOSSAL, R .
APPLIED OPTICS, 1981, 20 (12) :2097-2107
[4]  
BONNER RF, 1988, SCATTERING TECHNIQUE, P685
[5]   EFFECTS OF SPHERE SIZE AND INJECTION SITE ON REGIONAL CEREBRAL BLOOD-FLOW MEASUREMENTS [J].
CHEN, RYZ ;
FAN, FC ;
SCHUESSLER, GB ;
USAMI, S ;
CHIEN, S .
STROKE, 1983, 14 (05) :769-776
[6]   A MODEL OF FOCAL ISCHEMIC STROKE IN THE RAT - REPRODUCIBLE EXTENSIVE CORTICAL INFARCTION [J].
CHEN, ST ;
HSU, CY ;
HOGAN, EL ;
MARICQ, H ;
BALENTINE, JD .
STROKE, 1986, 17 (04) :738-743
[7]   HYBRID BLOOD-FLOW PROBE FOR SIMULTANEOUS H-2 CLEARANCE AND LASER-DOPPLER VELOCIMETRY [J].
DIRESTA, GR ;
KIEL, JW ;
RIEDEL, GL ;
KAPLAN, P ;
SHEPHERD, AP .
AMERICAN JOURNAL OF PHYSIOLOGY, 1987, 253 (04) :G573-G581
[8]   CONTINUOUS MEASUREMENT OF CEREBRAL CORTICAL BLOOD-FLOW BY LASER-DOPPLER FLOWMETRY IN A RAT STROKE MODEL [J].
DIRNAGL, U ;
KAPLAN, B ;
JACEWICZ, M ;
PULSINELLI, W .
JOURNAL OF CEREBRAL BLOOD FLOW AND METABOLISM, 1989, 9 (05) :589-596
[9]   A COMPARISON OF MEASUREMENTS OF CEREBRAL BLOOD-FLOW IN THE RABBIT USING LASER DOPPLER SPECTROSCOPY AND RADIONUCLIDE LABELED MICROSPHERES [J].
EYRE, JA ;
ESSEX, TJH ;
FLECKNELL, PA ;
BARTHOLOMEW, PH ;
SINCLAIR, JI .
CLINICAL PHYSICS AND PHYSIOLOGICAL MEASUREMENT, 1988, 9 (01) :65-74
[10]   INTRAOPERATIVE USE OF LASER DOPPLER IN THE STUDY OF CEREBRAL MICROVASCULAR CIRCULATION [J].
FASANO, VA ;
URCIUOLI, R ;
BOLOGNESE, P ;
MOSTERT, M .
ACTA NEUROCHIRURGICA, 1988, 95 (1-2) :40-48