INFLOW VERSUS DEOXYHEMOGLOBIN EFFECTS IN BOLD FUNCTIONAL MRI USING GRADIENT ECHOES AT 1.5 T

被引:179
作者
DUYN, JH
MOONEN, CTW
VANYPEREN, GH
DEBOER, RW
LUYTEN, PR
机构
[1] NIH,DIAGNOST RADIOL RES LAB,BETHESDA,MD 20892
[2] NIH,INVIVO NMR RES CTR,BETHESDA,MD 20892
[3] PHILIPS MED SYST,5680 DA BEST,NETHERLANDS
关键词
D O I
10.1002/nbm.1940070113
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
Modified gradient-echo MR techniques were applied to study the effects of inflow on functional brain imaging studies using visual and motor cortex stimulation. The results demonstrate that the large signal changes, seen in previously reported gradient-echo studies at 1.5-2.0 T, are dominated by direct inflow effects, in particular when using a large hip angle and a thin slice. The findings suggest that inflow-based functional imaging, along with Blood Oxygenation Level Dependent (BOLD) functional MRI, may play an important role in future research towards the functional organization of the human brain.
引用
收藏
页码:83 / 88
页数:6
相关论文
共 22 条
  • [1] TIME COURSE EPI OF HUMAN BRAIN-FUNCTION DURING TASK ACTIVATION
    BANDETTINI, PA
    WONG, EC
    HINKS, RS
    TIKOFSKY, RS
    HYDE, JS
    [J]. MAGNETIC RESONANCE IN MEDICINE, 1992, 25 (02) : 390 - 397
  • [2] PROCESSING STRATEGIES FOR TIME-COURSE DATA SETS IN FUNCTIONAL MRI OF THE HUMAN BRAIN
    BANDETTINI, PA
    JESMANOWICZ, A
    WONG, EC
    HYDE, JS
    [J]. MAGNETIC RESONANCE IN MEDICINE, 1993, 30 (02) : 161 - 173
  • [3] DYNAMIC MAPPING OF THE HUMAN VISUAL-CORTEX BY HIGH-SPEED MAGNETIC-RESONANCE-IMAGING
    BLAMIRE, AM
    OGAWA, S
    UGURBIL, K
    ROTHMAN, D
    MCCARTHY, G
    ELLERMANN, JM
    HYDER, F
    RATTNER, Z
    SHULMAN, RG
    [J]. PROCEEDINGS OF THE NATIONAL ACADEMY OF SCIENCES OF THE UNITED STATES OF AMERICA, 1992, 89 (22) : 11069 - 11073
  • [4] CHO ZH, 1993, 12TH P SMRM ANN M, P170
  • [5] DUYN J, 1993, 12TH ANN M SOC MAGN, P168
  • [6] DUYN J, 1993, 12TH ANN M SOC MAGN, P1386
  • [7] DYNAMIC MR IMAGING OF HUMAN BRAIN OXYGENATION DURING REST AND PHOTIC-STIMULATION
    FRAHM, J
    BRUHN, H
    MERBOLDT, KD
    HANICKE, W
    [J]. JMRI-JOURNAL OF MAGNETIC RESONANCE IMAGING, 1992, 2 (05): : 501 - 505
  • [8] FUNCTIONAL MRI OF HUMAN BRAIN ACTIVATION AT HIGH SPATIAL-RESOLUTION
    FRAHM, J
    MERBOLDT, KD
    HANICKE, W
    [J]. MAGNETIC RESONANCE IN MEDICINE, 1993, 29 (01) : 139 - 144
  • [9] HAJNAL JV, 1993, 12TH ANN M SOC MAGN, P166
  • [10] HAJNAL JV, 1992, 11TH ANN M SOC MAGN, P1023