RELIABILITY FOR MULTIPLE FREQUENCY BIOELECTRIC IMPEDANCE

被引:22
作者
CHUMLEA, WC
GUO, SS
BELLISARI, A
BAUMGARTNER, RN
SIERVOGEL, RM
机构
[1] WRIGHT STATE UNIV, DEPT PEDIAT, DAYTON, OH 45435 USA
[2] WRIGHT STATE UNIV, DEPT SOCIOL & ANTHROPOL, DAYTON, OH 45435 USA
[3] UNIV NEW MEXICO, SCH MED, CLIN NUTR RES LAB, ALBUQUERQUE, NM 87131 USA
[4] WRIGHT STATE UNIV, DEPT MATH & STAT, DAYTON, OH 45435 USA
[5] WRIGHT STATE UNIV, DEPT COMMUNITY HLTH, DIV HUMAN BIOL, DAYTON, OH 45435 USA
关键词
D O I
10.1002/ajhb.1310060207
中图分类号
Q98 [人类学];
学科分类号
030303 ;
摘要
Multifrequency impedance may help to quantify body fluid compartments and levels of hydration among individuals. Most studies of bioelectric impedance use impedance machines operating at a frequency of 50 kHz, and observer error is low. The present study evaluates multifrequency impedance measurements at 15 frequencies from 5 to 1,300 kHz to determine observer reliability in 20 White subjects of each sex, 18-65 years of age. Data were collected during two time periods so that a participant was measured by each of two observers during each period. There was an effect of frequency and sex on reliability. The intra- and inter-observer reliability for resistance and reactance were high with coefficients of reliability of greater than 95% at frequencies under about 500 kHz for resistance and under 100 kHz for reactance. Technical errors of measurement were generally stable across frequencies for resistance but became increasingly large above 100 kHz for reactance. Resistance measures of men were more reliable than those of women. Reliability was reduced at high frequencies which are potentially useful in determining body fluid volumes. There was no effect of age on reliability. (C) 1994 Wiley-Liss, Inc.
引用
收藏
页码:195 / 202
页数:8
相关论文
共 19 条
[1]  
Baumgartner R N, 1990, Exerc Sport Sci Rev, V18, P193
[2]   FAT-FREE MASS ESTIMATION BY THE 2-ELECTRODE IMPEDANCE METHOD [J].
BOULIER, A ;
FRICKER, J ;
THOMASSET, AL ;
APFELBAUM, M .
AMERICAN JOURNAL OF CLINICAL NUTRITION, 1990, 52 (04) :581-585
[3]  
BOULIER A, 1992, AM J CLIN NUTR, V55, P760
[4]   SPECIFIC RESISTIVITY USED TO ESTIMATE FAT-FREE MASS FROM SEGMENTAL BODY MEASURES OF BIOELECTRIC IMPEDANCE [J].
CHUMLEA, WC ;
BAUMGARTNER, RN ;
ROCHE, AF .
AMERICAN JOURNAL OF CLINICAL NUTRITION, 1988, 48 (01) :7-15
[5]  
CHUMLEA WC, 1990, AM J CLIN NUTR, V51, P902
[6]  
DUCROT H, 1970, PRESSE MED, V51, P2269
[7]  
ELSEN R, 1987, IN VIVO BODY COMPOSI, P184
[8]  
Fleiss JL, 1986, RELIABILITY MEASUREM
[9]  
HELENIUS MYT, 1987, HUM BIOL, V59, P271
[10]   RELIABILITY AND VALIDITY OF BIOELECTRICAL IMPEDANCE IN DETERMINING BODY-COMPOSITION [J].
JACKSON, AS ;
POLLOCK, ML ;
GRAVES, JE ;
MAHAR, MT .
JOURNAL OF APPLIED PHYSIOLOGY, 1988, 64 (02) :529-534