USE OF MAGNETIC-RESONANCE ANGIOGRAPHY IN THE PRETRANSPLANT EVALUATION OF PORTAL-VEIN PATHOLOGY

被引:29
作者
LEWIS, WD
FINN, JP
JENKINS, RL
CARRETTA, M
LONGMAID, HE
EDELMAN, RR
机构
[1] NEW ENGLAND DEACONESS HOSP, DEPT SURG, BOSTON, MA 02215 USA
[2] BETH ISRAEL HOSP, DEPT RADIOL, BOSTON, MA 02215 USA
[3] HARVARD UNIV, SCH MED, DEPT SURG, DIV HEPATOBILIARY SURG & LIVER TRANSPLANTAT, BOSTON, MA 02115 USA
[4] HARVARD UNIV, SCH MED, DEPT RADIOL, BOSTON, MA 02115 USA
关键词
D O I
10.1097/00007890-199307000-00011
中图分类号
R392 [医学免疫学]; Q939.91 [免疫学];
学科分类号
100102 ;
摘要
The assessment of portal vein patency in patients selected as candidates for orthotopic liver transplantation should be accomplished noninvasively and with great accuracy. Magnetic resonance angiography (MRA) is a new technique that is completely noninvasive and is capable of graphically assessing portal vein anatomy and blood flow. In an attempt to establish the accuracy of portal venous MRA, 74 patients with established cirrhosis underwent abdominal MRA prior to liver transplantation. MRA findings were correlated with surgical findings at the time of transplantation in all patients, and were shown to be extremely accurate. The three-dimensional images generated by MRA and computer postprocessing allowed for correct identification of portal venous anatomy in all of the patients examined. We conclude that MRA is an extremely useful method of determining portal venous anatomy in potential liver transplant patients, and potentially offers greater definition and clarity compared with other non-invasive methods.
引用
收藏
页码:64 / 68
页数:5
相关论文
共 24 条
  • [1] BLOOD-FLOW EFFECTS IN MAGNETIC-RESONANCE IMAGING
    AXEL, L
    [J]. AMERICAN JOURNAL OF ROENTGENOLOGY, 1984, 143 (06) : 1157 - 1166
  • [2] BURDICK JF, 1990, SURGERY, V197, P342
  • [3] DOPPLER FLOWMETRY AND PORTAL-HYPERTENSION
    BURNS, P
    TAYLOR, K
    BLEI, AT
    [J]. GASTROENTEROLOGY, 1987, 92 (03) : 824 - 826
  • [4] ANGIOGRAPHIC AND INTERVENTIONAL RADIOLOGIC CONSIDERATIONS IN LIVER-TRANSPLANTATION
    CARDELLA, JF
    CASTANEDAZUNIGA, WR
    HUNTER, D
    YOUNG, A
    AMPLATZ, K
    [J]. AMERICAN JOURNAL OF ROENTGENOLOGY, 1986, 146 (01) : 143 - 153
  • [5] CASTALDO P, 1991, AM J GASTROENTEROL, V86, P506
  • [6] CZERNIAK A, 1990, TRANSPLANTATION, V50, P334
  • [7] FRODO PULSE SEQUENCES - A NEW MEANS OF ELIMINATING MOTION, FLOW, AND WRAPAROUND ARTIFACTS
    EDELMAN, RR
    ATKINSON, DJ
    SILVER, MS
    LOAIZA, FL
    WARREN, WS
    [J]. RADIOLOGY, 1988, 166 (01) : 231 - 236
  • [8] MR ANGIOGRAPHY AND DYNAMIC FLOW EVALUATION OF THE PORTAL VENOUS SYSTEM
    EDELMAN, RR
    ZHAO, B
    LIU, C
    WENTZ, KU
    MATTLE, HP
    FINN, JP
    MCARDLE, C
    [J]. AMERICAN JOURNAL OF ROENTGENOLOGY, 1989, 153 (04) : 755 - 760
  • [9] SPATIAL PRESATURATION - A METHOD FOR SUPPRESSING FLOW ARTIFACTS AND IMPROVING DEPICTION OF VASCULAR ANATOMY IN MR IMAGING
    FELMLEE, JP
    EHMAN, RL
    [J]. RADIOLOGY, 1987, 164 (02) : 559 - 564
  • [10] FINN J P, 1992, Magnetic Resonance Quarterly, V8, P1