ROC ANALYSIS FOR POST-PROCESSING OF IMAGE DATA OF DIGITAL LUMINESCENCE RADIOGRAPHS OF THE THORAX

被引:11
作者
MULLER, RD [1 ]
HIRCHE, H [1 ]
VOSS, M [1 ]
BUDDENBROCK, B [1 ]
JOHN, V [1 ]
GOCKE, P [1 ]
机构
[1] UNIV ESSEN GESAMTHSCH KLINIKUM,INST MED INFORMAT BIOMETRIE & EPIDEMIOL,W-4300 ESSEN,GERMANY
来源
FORTSCHRITTE AUF DEM GEBIETE DER RONTGENSTRAHLEN UND DER NEUEN BILDGEBENDEN VERFAHREN | 1995年 / 162卷 / 02期
关键词
CHEST RADIOGRAPHY; DIGITAL STORAGE PHOSPHOR IMAGING; ROC-CURVE; ROC-ANALYSIS;
D O I
10.1055/s-2007-1015854
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To examine the extent to which digital luminescence radiography (DLR) can be used for the imaging of pulmonary nodules and interstitial lung disease in chest radiography without any loss of image quality. Additionally: to examine whether post-processing of image data can optimise the recognisability of varied image details. Materials and Methods: Detail perceptibility studies were performed on an anthropomorphic thorax phantom with simulated nodules and small linear and reticular details. Under standard conditions, digital luminescence radiographs were obtained in 7 different image modes, and these were compared with a 200-speed screen-film system. The detection of these systems was evaluated in an ROC analysis on the basis of 19 200 individual observations. Results: Edge enhancement or application of high-frequency-enhancing small filter kernels (S 5) slightly improves the detection of linear structures; however, the illustration of nodular details is markedly reduced. Larger filter kernels (S 20, S 40) make a definitive detection possible - not only of circular, but also of linear details. Conclusions: Storage phosphor radiographs are equal to the tested analog screen-film-system, The optimization of post-processing can be helpful in the prevention of routine multiple documentations.
引用
收藏
页码:163 / 169
页数:7
相关论文
共 30 条
[1]  
BUSCH HP, 1990, FORTSCHR RONTG NEUEN, V152, P412
[2]  
BUSCH HP, 1990, DIGITALE BILDGEBUNG, P174
[3]   INTERSTITIAL PULMONARY-DISEASE - A COMPARISON BETWEEN FILM-SCREEN TECHNIQUE AND DIGITAL STORAGE PHOSPHOR TECHNIQUE [J].
DOLKEN, W ;
CHOWANETZ, W ;
HORWITZ, AE ;
KRAHE, T ;
LANDWEHR, P ;
LACKNER, K .
FORTSCHRITTE AUF DEM GEBIETE DER RONTGENSTRAHLEN UND DER NEUEN BILDGEBENDEN VERFAHREN, 1992, 156 (01) :61-67
[4]  
Dorfman D. D., 1982, EVALUATION DIAGNOSTI, P212
[5]   DETECTION OF PNEUMOTHORAX - COMPARISON OF DIGITAL AND CONVENTIONAL CHEST IMAGING [J].
FAJARDO, LL ;
HILLMAN, BJ ;
POND, GD ;
CARMODY, RF ;
JOHNSON, JE ;
FERRELL, WR .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1989, 152 (03) :475-480
[6]  
FOLEY WD, 1986, INVEST RADIOL, V21, P305
[7]   PNEUMOTHORAX AND OTHER LUNG-DISEASES - EFFECT OF ALTERED RESOLUTION AND EDGE ENHANCEMENT ON DIAGNOSIS WITH DIGITIZED RADIOGRAPHS [J].
GOODMAN, LR ;
FOLEY, WD ;
WILSON, CR ;
TIKOFSKY, RS ;
HOFFMANN, RG .
RADIOLOGY, 1988, 167 (01) :83-88
[8]   DIGITAL RADIOGRAPHY OF THE CHEST - PROMISES AND PROBLEMS [J].
GOODMAN, LR ;
WILSON, CR ;
FOLEY, WD .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1988, 150 (06) :1241-1252
[9]  
ISHIDA M, 1987, COMPUTED RADIOGRAPHY
[10]  
KEHLER M, 1991, ACTA RADIOL, V32, P18