AN OUTBREAK OF OCHROBACTRUM-ANTHROPI BACTEREMIA IN 5 ORGAN TRANSPLANT PATIENTS

被引:55
作者
EZZEDINE, H
MOURAD, M
VANOSSEL, C
LOGGHE, C
SQUIFFLET, JP
RENAULT, F
WAUTERS, G
GIGI, J
WILMOTTE, L
HAXHE, JJ
机构
[1] CLIN UNIV ST LUC, DEPT MICROBIOL, B-1200 BRUSSELS, BELGIUM
[2] CLIN UNIV ST LUC, HOSP INFECT CONTROL SECT, B-1200 BRUSSELS, BELGIUM
[3] CLIN UNIV ST LUC, RENAL & PANCREAT TRANSPLANTAT UNIT, B-1200 BRUSSELS, BELGIUM
关键词
OCHROBACTRUM-ANTHROPI; MICROBACTERIUM; ANTI-THYMOCYTE GLOBULIN; BACTERIAL CONTAMINATION; BACTEREMIA;
D O I
10.1016/0195-6701(94)90066-3
中图分类号
R1 [预防医学、卫生学];
学科分类号
1004 ; 120402 ;
摘要
Nosocomial bacteraemia caused by Ochrobactrum anthropi occurred over a 1-month period in five organ transplant recipients, four of whom were in the same renal and pancreatic transplant unit. Bacteraemia occurred with cyclosporin A, azathioprine and steroids, and with a rabbit anti-thymocyte globulin (RATG) during the induction phase. RATG appeared to be the only common factor among the five cases. Over the period described, 71·4% of all patients receiving RATG developed O. anthropi bacteraemia. Three patients presented with fever and chills during or shortly after RATG infusion. Analysis of residues of the infusion, and the used vials of RATG, showed the presence of O. anthropi in concentrations of between 20 and 1000 cfu ml-1 in 5·3% of samples. Unused vials were found to be heavily contaminated with either O. anthropi or Microbacterium spp. in 23·5% of samples. All positive vials were of one particular lot number suggesting a malfunction in the manufacturing process. Many parenteral drugs such as the RATG used here do not contain preservatives and, although aseptically prepared, will not withstand thermal sterilization. Bacterial contamination of these small volume medications is not always easily detectable by conventional methods. This outbreak highlights the need for accurate quality control testing to detect small inocula that may occur during or after the manufacturing process. © 1994.
引用
收藏
页码:35 / 42
页数:8
相关论文
共 6 条
[1]   CATHETER-ASSOCIATED SEPSIS CAUSED BY OCHROBACTRUM-ANTHROPI - REPORT OF A CASE AND REVIEW OF RELATED NONFERMENTATIVE BACTERIA [J].
CIESLAK, TJ ;
ROBB, ML ;
DRABICK, CJ ;
FISCHER, GW .
CLINICAL INFECTIOUS DISEASES, 1992, 14 (04) :902-907
[2]   7 CASES OF BACTEREMIA DUE TO OCHROBACTRUM-ANTHROPI [J].
GRANSDEN, WR ;
EYKYN, SJ .
CLINICAL INFECTIOUS DISEASES, 1992, 15 (06) :1068-1069
[3]   NATIONWIDE EPIDEMIC OF SEPTICEMIA CAUSED BY CONTAMINATED INFUSION PRODUCTS .4. GROWTH OF MICROBIAL PATHOGENS IN FLUIDS FOR INTRAVENOUS-INFUSION [J].
MAKI, DG ;
MARTIN, WT .
JOURNAL OF INFECTIOUS DISEASES, 1975, 131 (03) :267-272
[4]   INFECTION CONTROL IN INTRAVENOUS THERAPY [J].
MAKI, DG ;
GOLDMNAN, DA ;
RHAME, FS .
ANNALS OF INTERNAL MEDICINE, 1973, 79 (06) :867-887
[5]  
WHYTE W, 1989, J PARENT SCI TECHN, V43, P208
[6]  
1971, MMWR-MORBID MORTAL W, V20, P91