IRREVERSIBLE REFRIGERATORS WITH ISOTHERMAL HEAT EXCHANGES

被引:38
作者
GRAZZINI, G
机构
[1] Dipartimento di Energetica, 50139 Firenze, Via di Santa Marta
来源
INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID | 1993年 / 16卷 / 02期
关键词
REFRIGERATORS; THERMODYNAMIC OPTIMIZATION; IRREVERSIBILITIES;
D O I
10.1016/0140-7007(93)90066-H
中图分类号
O414.1 [热力学];
学科分类号
摘要
A maximum for the coefficient of performance (COP(f)) is verified for a temperature difference between reservoirs and the hot isotherm of a closed irreversible cyclical refrigerator working at steady-state conditions. A maximum also exists when the COP(f) is considered as a function only of a parameter depending on the thermal characteristics of the heat exchangers. The influence of the parameter and entropy generation on the COP(f) maxima is described.
引用
收藏
页码:101 / 106
页数:6
相关论文
共 10 条
[2]  
Bejan A, 1988, ADV ENG THERMODYNAMI
[3]  
BLANCHARD CH, 1990, J APPL PHYS, V51, P2471
[4]  
BOREL L, 1984, THERMODYNAMIQUE ENER
[5]   EFFICIENCY OF A CARNOT ENGINE AT MAXIMUM POWER OUTPUT [J].
CURZON, FL ;
AHLBORN, B .
AMERICAN JOURNAL OF PHYSICS, 1975, 43 (01) :22-24
[6]   WORK FROM IRREVERSIBLE HEAT ENGINES [J].
GRAZZINI, G .
ENERGY, 1991, 16 (04) :747-755
[7]  
GRAZZINI G, 1990, FUTURE FOR ENERGY - FLOWERS 90, P473
[8]  
Kotas TJ, 2012, EXERGY METHOD THERMA
[9]  
LIANG HM, 1991, ENERGY, V16, P883, DOI 10.1016/0360-5442(91)90039-O
[10]  
YAN Z, 1990, FUTURE FOR ENERGY - FLOWERS 90, P193