EXPERIMENTAL SURFACE TENSIONS FOR HFC-32, HCFC-124, HFC-125, HCFC-141B, HCFC-142B, AND HFC-152A

被引:36
作者
OKADA, M [1 ]
HIGASHI, Y [1 ]
机构
[1] IWAKI MEISEI UNIV,DEPT MECH ENGN,IWAKI,FUKUSHIMA 970,JAPAN
关键词
DIFFERENTIAL CAPILLARY-RISE METHOD; HFC-32; HCFC-124; HFC-125; HCFC-141B; HCFC-142B; HFC-152A; REFRIGERANTS; SURFACE TENSION;
D O I
10.1007/BF01438864
中图分类号
O414.1 [热力学];
学科分类号
摘要
The surface tension of six alternative refrigerants, i.e., HFC-32 (CH2F2), HCFC-124 (CHCIFCF3), HFC-125 (CHF2CF3), HCFC-141b (CH(3)CC1(2)F), HCFC-142b (CH3CCIF2), and HFC-152a (CH3CHF2), has been measured in the present study. The measurements were conducted under equilibrium conditions between the liquid and its saturated vapor. The differential capillary-rise method (DCRM) used two glass capillaries, with inner radii of 0.3034 +/- 0.0002 and 0.5717 +/- 0.0002 mm, respectively. Temperatures in the range from 270 to 340 K were considered. The accuracy of surface tension measurements is estimated to be within +/- 0.2 mN . m(-1). The temperatures are accurate to within +/- 20 mK. The temperature dependence of the resultant data were successfully represented by van der Waals' correlations to within +/- 0.1 mN . m(-1) for each substance. Available surface tension data are compared with the present data.
引用
收藏
页码:791 / 800
页数:10
相关论文
共 25 条
[1]  
ARNAUD D, 1991, 13TH P INT C REFR MO, P621
[2]   ALTERNATIVE REFRIGERANTS R123A, R134, R141B, R142B, AND R152A - CRITICAL-TEMPERATURE, REFRACTIVE-INDEX, SURFACE-TENSION, AND ESTIMATES OF LIQUID, VAPOR, AND CRITICAL DENSITIES [J].
CHAE, HB ;
SCHMIDT, JW ;
MOLDOVER, MR .
JOURNAL OF PHYSICAL CHEMISTRY, 1990, 94 (25) :8840-8845
[3]  
DZELEZNIY VP, 1977, TEPLOFIZ SVOISTVA VE, V11, P55
[4]  
Fukushima M., 1993, T JPN SOC REFRIG AIR, V10, P75
[5]  
FUKUSHIMA M, 1992, T JAR, V9, P247
[6]   MEASUREMENTS OF VAPOR-PRESSURE, VAPOR LIQUID COEXISTENCE CURVE AND CRITICAL PARAMETERS OF REFRIGERANT 152A [J].
HIGASHI, Y ;
ASHIZAWA, M ;
KABATA, Y ;
MAJIMA, T ;
UEMATSU, M ;
WATANABE, K .
JSME INTERNATIONAL JOURNAL, 1987, 30 (265) :1106-1112
[7]   CRITICAL PARAMETERS FOR HFC134A, HFC32 AND HFC125 [J].
HIGASHI, Y .
INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 1994, 17 (08) :524-531
[8]  
HIGASHI Y, 1992, T JAR, V9, P191
[9]   LIQUID DENSITIES AND VAPOR-PRESSURES OF 1,1,2,2-TETRAFLUOROETHANE (HFC 134) AND 1,1-DICHLORO-1-FLUOROETHANE (HCFC 141B) [J].
MAEZAWA, Y ;
SATO, H ;
WATANABE, K .
JOURNAL OF CHEMICAL AND ENGINEERING DATA, 1991, 36 (02) :151-155
[10]   LIQUID DENSITIES AND VAPOR-PRESSURES OF 1-CHLORO-1,1-DIFLUOROETHANE (HCFC 142B) [J].
MAEZAWA, Y ;
SATO, H ;
WATANABE, K .
JOURNAL OF CHEMICAL AND ENGINEERING DATA, 1991, 36 (02) :148-150