RENAL BIOPSY IN DIFFUSE RENAL-DISEASE - EXPERIENCE WITH A 14-GAUGE AUTOMATED BIOPSY GUN

被引:45
作者
TUNG, KT
DOWNES, MO
ODONNELL, PJ
机构
[1] KENT & CANTERBURY HOSP,DEPT DIAGNOST RADIOL,ETHELBERT RD,CANTERBURY CT1 3NG,KENT,ENGLAND
[2] UNIV LONDON KINGS COLL HOSP,DEPT HISTOPATHOL,LONDON SE5 8RX,ENGLAND
关键词
D O I
10.1016/S0009-9260(05)80314-9
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
The diagnostic and complication rates of 104 percutaneous renal biopsies performed for diffuse renal disease in native kidneys were retrospectively reviewed. Biopsies were performed by one radiologist using continuous ultrasound guidance and a 14-gauge biopsy needle in an automated gun (Biopty TM, Radiplast TM, Uppsala). 103 of 104 (99%) biopsies resulted in adequate tissue for a definitive histological diagnosis which improves on previously published diagnostic rates. Four patients (3.8%) experienced transient macroscopic haematuria. There were two symptomatic peri-renal haematomas, both of whom required transfusion, and one arterio-venous fistula which was successfully embolized (total 2.9%) significant complications). Our results compare favourably with results using more conventional techniques. We suggest that use of real-time ultrasound with the 14-gauge Biopty needle should be the method of choice for percutaneous renal biopsy in adults.
引用
收藏
页码:111 / 113
页数:3
相关论文
共 27 条
[1]  
ALMKUIST RD, 1979, UROL CLIN N AM, V6, P503
[2]  
[Anonymous], 1988, Ann Intern Med, V108, P301
[3]  
BEAMAN M, 1989, BRIT J HOSP MED, V41, P158
[4]   AUTOMATED BIOPSY DEVICES - SIGNIFICANCE AND SAFETY [J].
BERNARDINO, ME .
RADIOLOGY, 1990, 176 (03) :615-616
[5]  
BIRHOLZ JC, 1985, KIDNEY INT, V27, P80
[6]   LOCALIZATION OF KIDNEY FOR PERCUTANEOUS BIOPSY - COMPARATIVE STUDY OF METHODS [J].
BOLTON, WK ;
TULLY, RJ ;
LEWIS, EJ ;
RANNIGER, K .
ANNALS OF INTERNAL MEDICINE, 1974, 81 (02) :159-164
[7]   RENAL BIOPSIES UNDER ULTRASOUND GUIDANCE - 100 CONSECUTIVE BIOPSIES IN CHILDREN [J].
CHAN, JCM ;
BREWER, WH ;
STILL, WJ .
JOURNAL OF UROLOGY, 1983, 129 (01) :103-107
[8]   THE IMPORTANCE OF SAMPLE-SIZE IN THE INTERPRETATION OF THE RENAL BIOPSY [J].
CORWIN, HL ;
SCHWARTZ, MM ;
LEWIS, EJ .
AMERICAN JOURNAL OF NEPHROLOGY, 1988, 8 (02) :85-89
[9]  
Diaz-Buxo J A, 1975, Clin Nephrol, V4, P223
[10]   EFFICACY OF AUTOMATED BIOPSY GUNS VERSUS CONVENTIONAL BIOPSY NEEDLES IN THE PYGMY PIG [J].
HOPPER, KD ;
BAIRD, DE ;
REDDY, VV ;
LANDIS, JR ;
PARKER, SH ;
TYLER, HN ;
OWNBEY, JL ;
MCCAUSLIN, MA ;
YAKES, WF ;
SABATELLI, FW ;
MOTT, PL .
RADIOLOGY, 1990, 176 (03) :671-676