PILOT-PLANT FOR FLUE-GAS TREATMENT - CONTINUOUS OPERATION TESTS

被引:23
作者
CHMIELEWSKI, AG [1 ]
TYMINSKI, B [1 ]
LICKI, J [1 ]
ILLER, E [1 ]
ZIMEK, Z [1 ]
RADZIO, B [1 ]
机构
[1] INST ATOM ENERGY,PL-05400 SWIERK ORWOCK,POLAND
来源
RADIATION PHYSICS AND CHEMISTRY | 1995年 / 46卷 / 4-6期
关键词
ELECTRON BEAM; FLUE GAS TREATMENT; NOX AND SO2 REMOVAL; BAG FILTER;
D O I
10.1016/0969-806X(95)00322-O
中图分类号
O64 [物理化学(理论化学)、化学物理学];
学科分类号
070304 ; 081704 ;
摘要
Tests of continous operation have been performed on pilot plant at EPS Kaweczyn in the wide range of SO2 concentration (500-3000 ppm). The bag filter has been applied for aerosol separation. The high efficiences of SO2 and NOx removal, approximately 90% were obtained and influenced by such process parameters as: dose, gas temperature and ammonia stoichiometry. The main apparatus of the pilot plant (e.g. both accelerators) have proved their reliability in hard industrial conditions.
引用
收藏
页码:1067 / 1070
页数:4
相关论文
共 5 条
[1]  
CHMIELEWSKI AG, 1992, RADIAT PHYS CHEM, V40, P321
[2]   PILOT-PLANT FOR FLUE-GAS TREATMENT WITH ELECTRON-BEAM START UP AND 2-STAGE IRRADIATION TESTS [J].
CHMIELEWSKI, AG ;
TYMINSKI, B ;
LICKI, J ;
ILLER, E ;
ZIMEK, Z ;
DOBROWOLSKI, A .
RADIATION PHYSICS AND CHEMISTRY, 1993, 42 (4-6) :663-668
[3]  
CHMIELEWSKI AG, 1994, IN PRESS RAD PHYS CH
[4]  
CHMIELEWSKI AG, 1992, IAEASA325124
[5]  
LICKI J, 1992, RADIAT PHYS CHEM, V40, P331