Cortical thickness assessed by peripheral quantitative computed tomography: Accuracy evaluated on radius specimens

被引:63
作者
Louis, O
Willnecker, J
Soykens, S
VandenWinkel, P
Osteaux, M
机构
[1] FREE UNIV BRUSSELS,AKAD ZIEKENHUIS,CYCLOTRON DEPT,B-1090 BRUSSELS,BELGIUM
[2] STRATEC MED TECH,BIRKENFELD,GERMANY
关键词
cortical thickness; peripheral quantitative computed tomography; radius;
D O I
10.1007/BF01626606
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
The purpose of the present study was to evaluate the accuracy of peripheral quantitative computed tomography (pQCT) in measuring the thickness of the radial cortex. Thirty left forearm specimens were scanned on an XCT 960 Stratec pQCT device using a 2.5 mm thick slice at the junction of the middle and the distal third of the radius. Cortical and trabecular areas were assessed using a threshold procedure; cortical thickness was subsequently calculated assuming a circular ring model for the radius. Cortical thickness was also measured on the true shape of bone using an iterative contour detection procedure. Subsequently 2.5 mm thick resin-embedded cylindrical radial specimens, matched with the site of pQCT examination, were obtained and contact radiographs were performed. After tenfold magnification, the cortical and trabecular areas of the specimens were measured using computerized planimetry and cortical thickness was calculated assuming a circular ring model. The cortical thickness could be assessed by pQCT in all cases using the threshold algorithm (mean (SD) 2.51 (0.58) mm) and in 21 cases could be directly measured on the true shape of bone (2.62 (0.32) mm). The cortical thickness of the specimens showed good correlation and high proportionality with that measured using pQCT with either the threshold algorithm (r = 0.941, slope = 0.976) or the iterative contour detection procedure (r = 0.883, slope = 0.987). In conclusion, pQCT is able to assess the thickness of the radial cortex, at the junction of the middle and the distal third, with high accuracy.
引用
收藏
页码:446 / 449
页数:4
相关论文
共 13 条
[1]   FOREARM BMD AS MEASURED BY PERIPHERAL QUANTITATIVE COMPUTED-TOMOGRAPHY (PQCT) IN A GERMAN REFERENCE POPULATION [J].
BUTZ, S ;
WUSTER, C ;
SCHEIDTNAVE, C ;
GOTZ, M ;
ZIEGLER, R .
OSTEOPOROSIS INTERNATIONAL, 1994, 4 (04) :179-184
[2]   BONE COMPRESSIVE STRENGTH - INFLUENCE OF DENSITY AND STRAIN RATE [J].
CARTER, DR ;
HAYES, WC .
SCIENCE, 1976, 194 (4270) :1174-1176
[3]   AUTOMATED COMPUTERIZED RADIOGRAMMETRY OF THE 2ND METACARPAL AND ITS CORRELATION WITH ABSORPTIOMETRY OF THE FOREARM AND SPINE [J].
DERISQUEBOURG, T ;
DUBOIS, P ;
DEVOGELAER, JP ;
MEYS, E ;
DUQUESNOY, B ;
DEDEUXCHAISNES, CN ;
DELCAMBRE, B ;
MARCHANDISE, X .
CALCIFIED TISSUE INTERNATIONAL, 1994, 54 (06) :461-465
[4]  
HANGARTNER TN, 1994, BONE MINER, V25, pS4
[5]   CROSS-SECTIONAL GEOMETRICAL PROPERTIES AND BONE-MINERAL CONTENTS OF THE HUMAN RADIUS AND ULNA [J].
HSU, ES ;
PATWARDHAN, AG ;
MEADE, KP ;
LIGHT, TR ;
MARTIN, WR .
JOURNAL OF BIOMECHANICS, 1993, 26 (11) :1307-1318
[6]  
LOUIS O, 1993, INVEST RADIOL, V28, P802
[7]   EXCISION OF A TRABECULAR ROI FROM RESIN-EMBEDDED VERTEBRAE - REPORT ON A COMPUTER-ASSISTED METHOD [J].
LOUIS, O ;
VANDENWINKEL, P ;
COVENS, P ;
SCHOUTENS, A ;
OSTEAUX, M .
PHYSICS IN MEDICINE AND BIOLOGY, 1993, 38 (06) :855-861
[8]   FRACTURE RISK - A ROLE FOR COMPACT-BONE [J].
MAZESS, RB .
CALCIFIED TISSUE INTERNATIONAL, 1990, 47 (04) :191-193
[9]   GEOMETRIC VARIABLES FROM DXA OF THE RADIUS PREDICT FOREARM FRACTURE LOAD INVITRO [J].
MYERS, ER ;
HECKER, AT ;
ROOKS, DS ;
HIPP, JA ;
HAYES, WC .
CALCIFIED TISSUE INTERNATIONAL, 1993, 52 (03) :199-204
[10]  
Ruegsegger P, 1991, Osteoporos Int, V1, P76, DOI 10.1007/BF01880447