INTERFACE FOR OPEN-TUBULAR COLUMN SUPERCRITICAL-FLUID CHROMATOGRAPHY ATMOSPHERIC-PRESSURE CHEMICAL-IONIZATION MASS-SPECTROMETRY

被引:45
作者
TYREFORS, LN [1 ]
MOULDER, RX [1 ]
MARKIDES, KE [1 ]
机构
[1] UNIV UPPSALA,DEPT ANALYT CHEM,POB 531,S-75121 UPPSALA,SWEDEN
关键词
D O I
10.1021/ac00068a021
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A new interface for open tubular column supercritical fluid chromatography (SFC) to atmospheric pressure chemical ionization mass spectrometry (APCI-MS) is described. The interface was designed to permit transport of the supercritical mobile phase into the ionization region of the mass spectrometer while maintaining its temperature to within +/- 1-degrees-C of the chromatographic oven temperature. Temperature control of the interface-transfer line was achieved using preheated gas streams from the chromatographic oven and an active electrical insulation. Ionization was achieved by a point-to-plane corona discharge. The performance of the SFC/MS interface is demonstrated using a number of selected analytes showing preserved chromatographic resolution, inertness in the transfer line, and independence of mobile-phase flow rate on ionization, as well as characterization of ionization and fragmentation patterns for compounds from different chemical classes. Test analytes included a polarity mixture over the solubility range of carbon dioxide. Minimum detectable quantities for anthracene and trilaurin were about 1 ng (S/N = 3) and 10 pg, respectively, while selected ion monitoring was used. An average retention time reproducibility of 0.24 % RSD was displayed with an average 2.6 % RSD in relative peak height. Retention time correlation between chromatograms obtained with flame ionization detection and mass spectrometric detection is also demonstrated.
引用
收藏
页码:2835 / 2840
页数:6
相关论文
共 11 条
  • [1] ANALYSIS OF POLYCYCLIC AROMATIC-COMPOUNDS BY SUPERCRITICAL FLUID CHROMATOGRAPHY MASS-SPECTROMETRY USING ATMOSPHERIC-PRESSURE CHEMICAL IONIZATION
    ANACLETO, JF
    RAMALEY, L
    BOYD, RK
    PLEASANCE, S
    QUILLIAM, MA
    SIM, PG
    BENOIT, FM
    [J]. RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 1991, 5 (04) : 149 - 155
  • [2] MASS-SPECTROMETRY
    BURLINGAME, AL
    BAILLIE, TA
    RUSSELL, DH
    [J]. ANALYTICAL CHEMISTRY, 1992, 64 (12) : R467 - R502
  • [3] SUBPICOGRAM DETECTION SYSTEM FOR GAS-PHASE ANALYSIS BASED UPON ATMOSPHERIC-PRESSURE IONIZATION (API) MASS-SPECTROMETRY
    CARROLL, DI
    DZIDIC, I
    STILLWELL, RN
    HORNING, MG
    HORNING, EC
    [J]. ANALYTICAL CHEMISTRY, 1974, 46 (06) : 706 - 710
  • [4] INTEGRAL PRESSURE RESTRICTOR FOR CAPILLARY SFC
    GUTHRIE, EJ
    SCHWARTZ, HE
    [J]. JOURNAL OF CHROMATOGRAPHIC SCIENCE, 1986, 24 (06) : 236 - 241
  • [5] NEW PICOGRAM DETECTION SYSTEM BASED ON A MASS-SPECTROMETER WITH AN EXTERNAL IONIZATION SOURCE AT ATMOSPHERIC-PRESSURE
    HORNING, EC
    HORNING, MG
    CARROLL, DI
    DZIDIC, I
    STILLWELL, RN
    [J]. ANALYTICAL CHEMISTRY, 1973, 45 (06) : 936 - 943
  • [6] PACKED-COLUMN SUPERCRITICAL FLUID CHROMATOGRAPHY MASS-SPECTROMETRY AND SUPERCRITICAL FLUID CHROMATOGRAPHY TANDEM MASS-SPECTROMETRY WITH IONIZATION AT ATMOSPHERIC-PRESSURE
    HUANG, E
    HENION, J
    COVEY, TR
    [J]. JOURNAL OF CHROMATOGRAPHY, 1990, 511 : 257 - 270
  • [7] LEE ML, 1990, ANAL SUPERCRITICAL F, pCH7
  • [8] MARKIDES KE, 1989, SFC APPLICATIONS
  • [9] OLESIK SV, 1991, HRC-J HIGH RES CHROM, V14, P5
  • [10] PERFORMANCE OF CAPILLARY RESTRICTORS IN SUPERCRITICAL FLUID CHROMATOGRAPHY
    SMITH, RD
    FULTON, JL
    PETERSEN, RC
    KOPRIVA, AJ
    WRIGHT, BW
    [J]. ANALYTICAL CHEMISTRY, 1986, 58 (09) : 2057 - 2064