BONE-ABLATION MECHANISM USING CO2-LASERS OF DIFFERENT PULSE DURATION AND WAVELENGTH

被引:93
作者
FORRER, M
FRENZ, M
ROMANO, V
ALTERMATT, HJ
WEBER, HP
SILENOK, A
ISTOMYN, M
KONOV, VI
机构
[1] RUSSIAN ACAD SCI,GEN INST PHYS,MOSCOW,RUSSIA
[2] UNIV BERN,INST PATHOL,CH-3012 BERN,SWITZERLAND
来源
APPLIED PHYSICS B-PHOTOPHYSICS AND LASER CHEMISTRY | 1993年 / 56卷 / 02期
关键词
D O I
10.1007/BF00325248
中图分类号
O59 [应用物理学];
学科分类号
摘要
Bone ablation using different pulse parameters and four emission lines of 9.3, 9.6, 10.3, and 10.6 mum of the CO2 laser exhibits effects which are caused by the thermal properties and the absorption spectrum of bone material. The ablation mechanism was investigated with light- and electron-microscopy at short laser-pulse durations of 0.9 and 1.8 mus and a long pulse of 250 mus. It is shown that different processes are responsible for the ablation mechanism either using the short or the long pulse durations. In the case of short pulse durations it is shown that, although the mineral components are the main absorber for CO2 radiation, water is the driving force for the ablation process. The destruction of material is based on explosive evaporation of water with an ablation energy of 1.3 kJ/cm3. Histological examination revealed a minimal zone of 10-15 mum of thermally altered material at the bottom of the laser drilled hole. Within the investigated spectral range we found that the ablation threshold at 9.3 and 9.6 mum is lower than at 10.3 and 10.6 mum. In comparison the ablation with a long pulse duration is determined by two processes. On the one side, the heat lost by heat conduction leads to carbonization of a surface layer, and the absorption of the CO2 radiation in this carbonized layer is the driving force of the ablation process. On the other side, it is shown that up to 60% of the pulse energy is absorbed in the ablation plume. Therefore, a long pulse duration results in an eight-times higher specific ablation energy of 10 kJ/cm3.
引用
收藏
页码:104 / 112
页数:9
相关论文
共 16 条
[1]   THEORY, MEASUREMENT, AND APPLICATION OF THERMAL PROPERTIES OF BIOMATERIALS [J].
BOWMAN, HF ;
CRAVALHO, EG ;
WOODS, M .
ANNUAL REVIEW OF BIOPHYSICS AND BIOENGINEERING, 1975, 4 :43-80
[2]   SPOT-SIZE MEASUREMENT OF AN INTENSE CO2-LASER BEAM [J].
DECKER, JE ;
XIONG, W ;
YERGEAU, F ;
CHIN, SL .
APPLIED OPTICS, 1992, 31 (12) :1912-1913
[3]  
FRENZ M, 1990, P SOC PHOTO-OPT INS, V1202, P22, DOI 10.1117/12.17608
[4]   ABLATION OF CALCIFIED BIOLOGICAL TISSUE USING PULSED HYDROGEN-FLUORIDE LASER-RADIATION [J].
IZATT, JA ;
SANKEY, ND ;
PARTOVI, F ;
FITZMAURICE, M ;
RAVA, RP ;
ITZKAN, I ;
FELD, MS .
IEEE JOURNAL OF QUANTUM ELECTRONICS, 1990, 26 (12) :2261-2270
[5]  
MEYER DR, 1990, LASER SURG MED, V6, P150
[6]   INFRARED-LASER BONE ABLATION [J].
NUSS, RC ;
FABIAN, RL ;
SARKAR, R ;
PULIAFITO, CA .
LASERS IN SURGERY AND MEDICINE, 1988, 8 (04) :381-391
[7]  
NYQUIST RA, 1971, INFRARED SPECTRA INO, P162
[8]   LAMBERT ABSORPTION COEFFICIENTS OF WATER IN INFRARED [J].
ROBERTSO.CW ;
WILLIAMS, D .
JOURNAL OF THE OPTICAL SOCIETY OF AMERICA, 1971, 61 (10) :1316-&
[9]  
SCHOLZ C, 1990, OPTOELECTRONICS MED, P67
[10]   CO-MGF2 LASER ABLATION OF TISSUE - EFFECT OF WAVELENGTH ON ABLATION THRESHOLD AND THERMAL-DAMAGE [J].
SCHOMACKER, KT ;
DOMANKEVITZ, Y ;
FLOTTE, TJ ;
DEUTSCH, TF .
LASERS IN SURGERY AND MEDICINE, 1991, 11 (02) :141-151