DETERMINATION OF PESTICIDES IN AQUEOUS SAMPLES BY SOLID-PHASE MICROEXTRACTION IN-LINE COUPLED TO GAS-CHROMATOGRAPHY MASS-SPECTROMETRY

被引:117
作者
EISERT, R [1 ]
LEVSEN, K [1 ]
机构
[1] FRAUNHOFER INST TOXICOL & AEROSOL RES, DEPT ANALYT CHEM, D-30625 HANNOVER, GERMANY
关键词
D O I
10.1016/1044-0305(95)00527-7
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
A multiresidue method was developed for the determination of nitrogen- and phosphorous-containing pesticides (amines, anilides, phosphorothioates, and triazines) by solid-phase microextraction (SPME) in-line coupled to gas chromatography-mass spectrometry (GC/MS). The 85-mu m polyacrylate fiber was first dipped into the aqueous sample for a given time and then directly introduced into the heated injector of the gas chromatography-mass spectrometer, where the analytes are thermally desorbed. The method was evaluated with respect to the limit of detection, linearity, and precision. The limit of detection [selected ion monitoring (SIM) mode] depends on the compound and varies from 5 to 90 ng/L. The method is linear over at least 3 orders of magnitude with coefficients of correlation usually greater than or equal to 0.996. In general, the coefficient of variation (precision) is <10%. The partitioning of the analyte between the aqueous phase and the polymeric phase depends on the hydrophobicity of the compound as expressed by the octanol-water partitioning coefficient P-ow. The addition of sodium chloride has a strong effect on the extraction efficiency. This effect increases with decreasing hydrophobicity (increasing polarity) of the compound. The triazines atrazine, simazine, and terbuthylazine were first identified and quantified in water samples from the effluent of sewage plants by SPME-gas chromatography-nitrogen-phosphorus detection (GC/NPD). For such a complex matrix GC/NPD is not sufficiently selective for an unambiguous identification at low levels (<1 ppb) of pesticides. Selectivity may be enhanced by using SMPE-GC/MS in the SIM mode with three characteristic ions for each pesticide. This method allows an unequivocal identification and quantification at low levels of pesticides in environmental samples. At a target limit of detection below 100 ng/L, SPME-GC/MS represents a very simple, fast, selective, and solvent-free multimethod for the extraction and determination of these nitrogen- and phosphorous-containing pesticides from aqueous samples.
引用
收藏
页码:1119 / 1130
页数:12
相关论文
共 37 条
  • [1] ARTHUR CL, 1992, HRC-J HIGH RES CHROM, V15, P741
  • [2] SOLID-PHASE MICROEXTRACTION WITH THERMAL-DESORPTION USING FUSED-SILICA OPTICAL FIBERS
    ARTHUR, CL
    PAWLISZYN, J
    [J]. ANALYTICAL CHEMISTRY, 1990, 62 (19) : 2145 - 2148
  • [3] ARTHUR CL, 1992, LC GC-MAG SEP SCI, V10, P656
  • [4] AUTOMATION AND OPTIMIZATION OF SOLID-PHASE MICROEXTRACTION
    ARTHUR, CL
    KILLAM, LM
    BUCHHOLZ, KD
    PAWLISZYN, J
    BERG, JR
    [J]. ANALYTICAL CHEMISTRY, 1992, 64 (17) : 1960 - 1966
  • [5] SOLVENTLESS INJECTION TECHNIQUE FOR MICROCOLUMN SEPARATIONS
    ARTHUR, CL
    CHAI, M
    PAWLISZYN, J
    [J]. JOURNAL OF MICROCOLUMN SEPARATIONS, 1993, 5 (01) : 51 - 56
  • [6] ARTHUR CL, 1992, J ENV SCI TECHNOL, V26, P979
  • [7] Belardi R.P., 1989, WATER POLLUT RES J C, V24, P179, DOI DOI 10.2166/WQRJ.1989.010
  • [8] BERG JR, 1993, AM LAB, V25, P18
  • [9] SOLID-PHASE EXTRACTION FOR MULTI-RESIDUE ANALYSIS OF SOME TRIAZOLE AND PYRIMIDINE PESTICIDES IN WATER
    BOLYGO, E
    ATREYA, NC
    [J]. FRESENIUS JOURNAL OF ANALYTICAL CHEMISTRY, 1991, 339 (06): : 423 - 430
  • [10] OPTIMIZATION OF SOLID-PHASE MICROEXTRACTION CONDITIONS FOR DETERMINATION OF PHENOLS
    BUCHHOLZ, KD
    PAWLISZYN, J
    [J]. ANALYTICAL CHEMISTRY, 1994, 66 (01) : 160 - 167