MEASUREMENT OF FINGER JOINT ANGLES AND MAXIMUM FINGER FORCES DURING CYLINDER GRIP ACTIVITY

被引:70
作者
LEE, JW [1 ]
RIM, K [1 ]
机构
[1] UNIV IOWA, IOWA INST BIOMED ENGN, DEPT BIOMED ENGN, IOWA CITY, IA 52242 USA
来源
JOURNAL OF BIOMEDICAL ENGINEERING | 1991年 / 13卷 / 02期
关键词
FINGER FORCES; CYLINDRICAL GRIP; JOINT ANGLES; PHOTOGRAMMETRY; PRESSURE-SENSITIVE FILM;
D O I
10.1016/0141-5425(91)90062-C
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Finger joint angles and finger forces during maximal cylindrical grasping were measured using multi-camera photogrammetry and pressure-sensitive sheets, respectively. The experimental data were collected from four healthy subjects gripping cylinders of five different sizes. For joint angles, an image analysis system was used to digitize slides showing markers. During the calibration of the camera system, both the nonlinear least square and the direct linear transform methods were applied and compared, the former providing the fewer errors; it was used to determine joint angles. Data were collected from the pressure-sensitive grip films by using the same image analysis system as used in the collection of the joint angle data. The method of using pressure-sensitive sheets provided an estimation of the weighted centre of the phalangeal forces. Results indicate that finger flexion angles at the metacarpophalangeal and proximal interphalangeal joints gradually increase as cylinder diameter decreases, but that at the distal interphalangeal joint the angle remains constant throughout all cylinder sizes. It was also found that most of the radio-ulnar deviation and the axial rotation angles at the finger joints deviate from zero, but the deviations are small. For the force measurement, it was found that total finger force increases as cylinder size decreases, and the phalangeal force centres are not located at the mid-points of the phalanges. The data obtained in this experiment would be useful for muscle force predictions and for the design of handles.
引用
收藏
页码:152 / 162
页数:11
相关论文
共 19 条
[1]  
ABDELAZIZ YI, 1971, P ASP UI S CLOSE RAN
[2]   VARIATION OF FINGER FORCES IN MAXIMAL ISOMETRIC GRASP TESTS ON A RANGE OF CYLINDER DIAMETERS [J].
AMIS, AA .
JOURNAL OF BIOMEDICAL ENGINEERING, 1987, 9 (04) :313-320
[3]  
An K. N., 1978, 1978 Advances in Bioengineering, P89
[4]   FORCES IN THE NORMAL AND ABNORMAL HAND [J].
AN, KN ;
CHAO, EY ;
COONEY, WP ;
LINSCHEID, RL .
JOURNAL OF ORTHOPAEDIC RESEARCH, 1985, 3 (02) :202-211
[5]   A SIMPLE METHOD OF MEASURING THE FOOTSOLE PRESSURE OF NORMAL SUBJECTS USING PRESCALE PRESSURE-DETECTING SHEETS [J].
ARITOMI, H ;
MORITA, M ;
YONEMOTO, K .
JOURNAL OF BIOMECHANICS, 1983, 16 (02) :157-165
[6]   3-DIMENSIONAL FORCE ANALYSIS OF FINGER JOINTS IN SELECTED ISOMETRIC HAND FUNCTIONS [J].
CHAO, EY ;
OPGRANDE, JD ;
AXMEAR, FE .
JOURNAL OF BIOMECHANICS, 1976, 9 (06) :387-396
[7]   GRAPHICAL INTERPRETATION OF SOLUTION TO REDUNDANT PROBLEM IN BIOMECHANICS [J].
CHAO, EY ;
AN, KN .
JOURNAL OF BIOMECHANICAL ENGINEERING-TRANSACTIONS OF THE ASME, 1978, 100 (03) :159-167
[8]  
Gentleman W. M., 1973, Journal of the Institute of Mathematics and Its Applications, V12, P329
[9]  
MARZAN GT, 1975, S CLOSE RANGE PHOTOG, P420
[10]   EFFECT OF ELBOW POSITION ON GRIP AND KEY PINCH STRENGTH [J].
MATHIOWETZ, V ;
RENNELS, C ;
DONAHOE, L .
JOURNAL OF HAND SURGERY-AMERICAN VOLUME, 1985, 10A (05) :694-697