ON THE TECHNIQUE OF EXTRAPOLATION TO OBTAIN WALL CORRECTION FACTORS FOR ION CHAMBERS IRRADIATED BY PHOTON BEAMS

被引:27
作者
BIELAJEW, AF
机构
[1] Institute for National Measurement Standards, National Research Council of Canada, Ottawa
关键词
extrapolation measurements wall correction wall perturbation ion chambers; Monte Carlo;
D O I
10.1118/1.596547
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 [临床医学]; 100207 [影像医学与核医学]; 1009 [特种医学];
摘要
Wall correction factors, which correct ion chamber response for photon attenuation and scatter, can differ by as much as 1.0% for spherical chambers depending on whether they are obtained experimentally by extrapolation measurements or by Monte Carlo simulation. This difference is not explained by experimental or calculational statistics which lie in the range 0.05%-0.2%. In this paper it is demonstrated that linear extrapolation of experimental data for spherical chambers is inappropriate, owing to the curvature of the chamber walls. A simple nonlinear theory is constructed that resolves the difference. The Monte Carlo calculations and the nonlinear theory are compared with extrapolation measurements for the NIST (formerly NBS) spherical chambers. It is concluded that wall correction factors should be obtained by Monte Carlo calculation for spherical chambers and that linear-extrapolation techniques should be regarded with suspicion for all chambers. © 1990, American Association of Physicists in Medicine. All rights reserved.
引用
收藏
页码:583 / 587
页数:5
相关论文
共 16 条
[1]
[Anonymous], [No title captured]
[2]
AN ANALYTIC THEORY OF THE POINT-SOURCE NONUNIFORMITY CORRECTION FACTOR FOR THICK-WALLED IONIZATION CHAMBERS IN PHOTON BEAMS [J].
BIELAJEW, AF .
PHYSICS IN MEDICINE AND BIOLOGY, 1990, 35 (04) :517-538
[3]
CORRECTION FACTORS FOR THICK-WALLED IONIZATION CHAMBERS IN POINT-SOURCE PHOTON BEAMS [J].
BIELAJEW, AF .
PHYSICS IN MEDICINE AND BIOLOGY, 1990, 35 (04) :501-516
[4]
THE MONTE-CARLO SIMULATION OF ION-CHAMBER RESPONSE TO CO-60 - RESOLUTION OF ANOMALIES ASSOCIATED WITH INTERFACES [J].
BIELAJEW, AF ;
ROGERS, DWO ;
NAHUM, AE .
PHYSICS IN MEDICINE AND BIOLOGY, 1985, 30 (05) :419-427
[5]
BIELAJEW AF, 1987, NUCL INSTRUM METH B, V18, P165
[6]
BIELAJEW AF, 1986, PHYS MED BIOL, V30, P161
[7]
COSTRELL L., 1962, HEALTH PHYS, V8, P491, DOI 10.1097/00004032-196210000-00002
[8]
EFFECT OF FINITE SIZE OF IONIZATION CHAMBERS ON MEASUREMENTS OF SMALL PHOTON SOURCES [J].
KONDO, S ;
RANDOLPH, ML .
RADIATION RESEARCH, 1960, 13 (01) :37-60
[9]
STANDARDIZATION OF CO-60 AND CS-137 GAMMA-RAY BEAMS IN TERMS OF EXPOSURE [J].
LOFTUS, TP ;
WEAVER, JT .
JOURNAL OF RESEARCH OF THE NATIONAL BUREAU OF STANDARDS SECTION A-PHYSICS AND CHEMISTRY, 1974, A 78 (04) :465-476
[10]
CALCULATED RESPONSE AND WALL CORRECTION FACTORS FOR IONIZATION CHAMBERS EXPOSED TO CO-60 GAMMA-RAYS - COMMENTS [J].
MCEWAN, AC ;
SMYTH, VG .
MEDICAL PHYSICS, 1984, 11 (02) :216-218