COLD PRODUCTION THROUGH COUPLING OF SOLID-GAS REACTORS .2. PERFORMANCE OF A PILOT INSTALLATION OF 1 TO 2-K W

被引:9
作者
LEPINASSE, E
SPINNER, B
机构
[1] CNRS-IMP (Institut de Science et de Génie des Matériaux et Procédés), Laboratoire Europeen Associe-SIMAP (Science et Ingenierie des Materiaux et Procedes), Université
来源
INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID | 1994年 / 17卷 / 05期
关键词
HEAT PUMP; SORPTION; SORPTION SYSTEM; SOLID GAS; CHLORIDE; AMMONIA;
D O I
10.1016/0140-7007(94)90062-0
中图分类号
O414.1 [热力学];
学科分类号
摘要
The feasibility of cold production by coupling of two reactors exchanging the reactive gas ammonia has been realized on a pilot plant of cold production, in the order of 1-2 kW. The chosen reagents are BaCl2 8/0 NH3 and MnCl2 6/2 NH3. The selection of calander-tube reactors makes possible the effective production of cold to the thermal fluid at an average of 500 W kg-1; the duration of this production is 30 min. The obtained experimental COP on the pilot plant is 0.35; optimization of the form and size of the reactors would allow further improvement of the COP in the vicinity of 0.58. The comprehension of the dynamic interaction between the two reactors makes it possible to preview the modelling of double effect systems.
引用
收藏
页码:323 / 328
页数:6
相关论文
共 12 条
[1]   A MODEL FOR REVERSIBLE SOLID GAS REACTIONS SUBMITTED TO TEMPERATURE AND PRESSURE CONSTRAINTS - SIMULATION OF THE RATE OF REACTION IN SOLID GAS REACTOR USED AS CHEMICAL HEAT-PUMP [J].
GOETZ, V ;
MARTY, A .
CHEMICAL ENGINEERING SCIENCE, 1992, 47 (17-18) :4445-4454
[2]  
LEBRUN M, 1989, Patent No. 8900268
[3]  
LEBRUN M, 1989, Patent No. 8913913
[4]  
Lepinasse E, 1994, REV INT FROID, V17, P309
[5]  
LEPINASSE E, 1992, THESIS PERPIGNAN
[6]   MICROCALORIMETRIC ANALYSIS OF THE REACTIVITY OF 2 MANGANESE CHLORIDE AMMONIATES [J].
MARTY, A .
JOURNAL OF THERMAL ANALYSIS, 1991, 37 (03) :479-498
[7]  
MARTY A, 1992, ETUDE MICROCALORIMET
[8]   HEAT AND MASS-TRANSFER IN CONSOLIDATED REACTING BEDS FOR THERMOCHEMICAL SYSTEMS [J].
MAURAN, S ;
PRADES, P ;
LHARIDON, F .
HEAT RECOVERY SYSTEMS & CHP, 1993, 13 (04) :315-319
[9]  
MAURAN S, 1990, THESIS U PERPIGNAN
[10]  
MOUTAABBIB M, 1986, THESIS U BOURGOGNE