SIMULTANEOUS MEASUREMENT OF 2 CELLULAR ANTIGENS AND DNA USING FLUORESCEIN-ISOTHIOCYANATE, R-PHYCOERYTHRIN, AND PROPIDIUM IODIDE ON A STANDARD FACSCAN

被引:39
作者
CORVER, WE
CORNELISSE, CJ
FLEUREN, GJ
机构
[1] Department of Pathology, University of Leiden, Leiden
来源
CYTOMETRY | 1994年 / 15卷 / 02期
关键词
TRIPLE FLUORESCENCE; FLOW CYTOMETRY; SURFACE MARKER; INTERMEDIATE FILAMENTS; LYSOLECITHIN; OVARIAN CANCER; DNA-PLOIDY;
D O I
10.1002/cyto.990150205
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Multiparameter flow cytometry is a powerful tool for analyzing the phenotypic, cell kinetic, and ploidy heterogeneity of tumor cell populations. Because of the substantial spectral overlap of propidium iodide (PI) and R-phycoerythrin (PE) fluorescence emission, this combined use of these fluorochromes has been thought not to be feasible on a standard flow cytometer for these kind of studies. Instead of PI, 7-amino-actinomycin D (7-AAD) is used as DNA stain. In this paper however, we show that PI can be used as a DNA stain in combination with fluorescein isothiocyanate (FITC) and R-phycoerythrin (PE) on a standard FACScan. Three established ovarian cancer cell lines (IGROV1, NIH: OVCAR-3, and COV362.c14) were used for these experiments. Cells were fixed with 1.0% paraformaldehyde and permeabilized with various concentrations of lysolecithin for the simultaneous detection of surface antigens by monoclonal antibodies MOv18, BMA180 or OV632, intermediate filament antigens (keratin 18 or vimentin), and DNA. A final concentration of 80 mu g/ml lysolecithin was found to give optimal results. The emission spectrum overlap from PI into the orange fluorescence channel (FL2) used for PE fluorescence detection could be sufficiently compensated up to a photomultiplier tube potential of about 440 Volts (V) required at the FL2 channel. Using the same instrument settings, 5.10 x 10(4) PE equivalents were detectable. Under these conditions, CVs obtained for the DNA histograms ranged from 3.0-4.1. Application of the method on a mixture of activated peripheral blood lymphocytes and ovarian tumor cells resulted in a clear separation of the two populations both by surface and cytoplasmic antigen expression and DNA content. (C) 1994 Wiley-Liss, Inc.
引用
收藏
页码:117 / 128
页数:12
相关论文
共 27 条
  • [1] CELL KINETIC-ANALYSIS OF MIXED POPULATIONS USING 3-COLOR FLUORESCENCE FLOW-CYTOMETRY
    BEGG, AC
    HOFLAND, I
    [J]. CYTOMETRY, 1991, 12 (05): : 445 - 454
  • [2] BENARD J, 1985, CANCER RES, V45, P4970
  • [3] BOSSLET K, 1987, INVEST NEW DRUG, V5, P93
  • [4] CONEY LR, 1991, CANCER RES, V51, P6125
  • [5] IMMUNOCYTOCHEMISTRY OF MALIGNANT MESOTHELIOMA - OV632 AS A MARKER OF MALIGNANT MESOTHELIOMA
    DELAHAYE, M
    HOOGSTEDEN, HC
    VANDERKWAST, TH
    [J]. JOURNAL OF PATHOLOGY, 1991, 165 (02) : 137 - 143
  • [6] SIMULTANEOUS PAIRED ANALYSIS BY FLOW-CYTOMETRY OF SURFACE-MARKERS, CYTOPLASMIC ANTIGENS, OR ONCOGENE EXPRESSION WITH DNA CONTENT
    DENT, GA
    LEGLISE, MC
    PRYZWANSKY, KB
    ROSS, DW
    [J]. CYTOMETRY, 1989, 10 (02): : 192 - 198
  • [7] FLEUREN GJ, 1987, VIRCHOWS ARCH A, V410, P481
  • [8] GILL JE, 1975, J HISTOCHEM CYTOCHEM, V11, P793
  • [9] HAMILTON TC, 1983, CANCER RES, V43, P5379
  • [10] HOWARD FD, 1981, J IMMUNOL, V126, P2117