摘要
The influence of the sampling chamber dimensions upon particle size estimation by cascade impaction has been investigated and compared with measurements by the twin impinger. Aerosols of salbutamol and disodium fluorescein (DF) were generated from pressurized metered dose inhalers. The mass median aerodynamic diameter (MMAD) by the Andersen Impactor for salbutamol ranged from 2.0 to 2.8-mu-m with geometric standard deviations (g.s.d.) of 1.7 to 2.4. These observations were independent of the distance travelled to the first impaction surface of the impactor and volume of the sampling chamber. The DF MMAD ranged from 5.0 to 6.9-mu-m with g.s.d. values of 1.7 to 1.8. Changes in droplet size within the sampling chamber may cause significant differences in particle size estimates as indicated by the cascade impaction data for DF. The respirable fraction of the salbutamol samples was similar whether determined by impaction or using the impinger. The latter device has previously been indicated to give clinically relevant estimates of respirable fraction for commercial inhalation aerosol devices.
引用
收藏
页码:726 / 728
页数:3
相关论文
共 19 条
[1]   A SAMPLER FOR RESPIRATORY HEALTH HAZARD ASSESSMENT [J].
ANDERSEN, AA .
AMERICAN INDUSTRIAL HYGIENE ASSOCIATION JOURNAL, 1966, 27 (02) :160-&
[2]   NEW SAMPLER FOR THE COLLECTION, SIZING, AND ENUMERATION OF VIABLE AIRBORNE PARTICLES [J].
ANDERSEN, AA .
JOURNAL OF BACTERIOLOGY, 1958, 76 (05) :471-484
[3]   COMPARISON OF OUTPUT PARTICLE-SIZE DISTRIBUTIONS FROM PRESSURIZED AEROSOLS FORMULATED AS SOLUTIONS OR SUSPENSIONS [J].
DALBY, RN ;
BYRON, PR .
PHARMACEUTICAL RESEARCH, 1988, 5 (01) :36-39
[4]  
DIEM K, 1968, SCI TABLES, P281
[5]  
FULTS K, 1990, PHARMACEUT RES, V7, pS5
[7]   THE TWIN IMPINGER - A SIMPLE DEVICE FOR ASSESSING THE DELIVERY OF DRUGS FROM METERED DOSE PRESSURIZED AEROSOL INHALERS [J].
HALLWORTH, GW ;
WESTMORELAND, DG .
JOURNAL OF PHARMACY AND PHARMACOLOGY, 1987, 39 (12) :966-972
[8]   EFFECTS OF SURFACTANTS ON AEROSOL POWDERS IN SUSPENSION - IMPLICATIONS FOR AIRBORNE PARTICLE-SIZE [J].
HICKEY, AJ ;
DALBY, RN ;
BYRON, PR .
INTERNATIONAL JOURNAL OF PHARMACEUTICS, 1988, 42 (1-3) :267-270
[9]   AN INVESTIGATION OF SIZE DEPOSITION UPON INDIVIDUAL STAGES OF A CASCADE IMPACTOR [J].
HICKEY, AJ .
DRUG DEVELOPMENT AND INDUSTRIAL PHARMACY, 1990, 16 (12) :1911-1929
[10]  
Hickey AJ, 1990, PHARM TECH, V14, P118