AEROSOL DERIVED AIRWAY MORPHOMETRY AT DIFFERENT LEVELS OF LUNG-INFLATION

被引:19
作者
BRAND, P
BEINERT, T
FRUHMANN, G
HILLEBRECHT, A
HEYDER, J
机构
[1] GSF—Forschungszentrumfür Umwelt und Gesundheit, Projekt Inhalation, Neuherberg
[2] Ludwig-Maximilian-Unlversität, Med. Klinik I, Department of Pneumology, München
来源
JOURNAL OF AEROSOL MEDICINE-DEPOSITION CLEARANCE AND EFFECTS IN THE LUNG | 1993年 / 6卷 / 03期
关键词
AEROSOL DERIVED AIRWAY MORPHOMETRY; AIRSPACE DIMENSIONS; HEALTHY SUBJECTS; LUNG VOLUME; PROXIMAL SHIFT; ISOTROPIC LUNG INFLATION;
D O I
10.1089/jam.1993.6.165
中图分类号
R1 [预防医学、卫生学];
学科分类号
1004 ; 120402 ;
摘要
Monodisperse aerosol particles can be used to estimate intrapulmonary air-space dimensions. However, effective air-space diameters (EAD) measured by this technique as a function of volumetric lung depth are dependent on lung inflation, which may be different between subjects with different lung volumes. In an attempt to achieve better comparability of EAD among subjects, the influence of the level of lung inflation on air-space dimensions was investigated in a group of 9 healthy subjects. The results showed that EAD increased with lung volume nearly linearly in peripheral lung regions whereas the increase in proximal regions was steeper and more heterogeneous within the group. This result can be understood when two mechanisms for a change in air-space diameter in a fixed volumetric lung depth are assumed: (1) a real increase in air-space caliber, (2) an apparent increase induced by a change of the anatomical site associated with a fixed volumetric lung depth (proximal shift). When the volumetric lung depth is normalized to the actual lung volume a visible reduction of the influence of lung volume on the measurement of EAD is observed. Differences in EAD among individuals are now better detectable, even when lung volumes are not comparable. Although this normalization considerably reduces the inter- and intraindividual scattering of EAD, the observation that the magnitude of the change in EAD with lung volume is different for different volumetric compartments of the lungs indicates that the assumptions underlying the normalization approach are not valid in a strict sense. Therefore, the normalization procedure presented in this paper cannot be used for physiological studies of airway distension.
引用
收藏
页码:165 / 176
页数:12
相关论文
共 15 条
[1]  
BEINERT T., BEHR J., BRAND P., HUBER A., REISINGER H., SCHULZ H., FRUHMANN G., HEYDER J., Aerosol morphometry and aerosol dispersion to study obstructive lung disease, Amer. Rev. Respir. Dis., 141, (1990)
[2]  
BEINERT T., BRAND P., BEHR J., SCHULZ H., SCHWAIBLMAIR M., FRUHMANN G., HEYDER J., Aerosol derived intrapulmonary airspace dimensions in emphysematic patients, European Respiratory Journal, 10, (1990)
[3]  
BENNETT W.D., MITZNER W., Use of aerosols to measure in vivo volume-dependent changes in lung air space dimensions, J. Appl. Physiol., 59, (1985)
[4]  
FELDMAN H.A., Families of lines: random effects in linear regression analysis, J, Appl. Physiol., 64, (1988)
[5]  
GEBHART J., HEIGWER G., HEYDER J., ROTH C., STAHLHOFEN W., The use of light scattering photometry in aerosol medicine, J. Aerosol Med., 1, (1988)
[6]  
HEYDER J., Gravitational deposition of aerosol particles within a system of randomly orientated tubes, J. Aerosol Sci., 6, (1975)
[7]  
HEYDER J., Assessment of airway geometry with inert aerosols, J. Aerosol Med., 2, (1989)
[8]  
HUGHES J.M.B., HOPPIN F.G., MEAD J., Effect of lung inflation on bronchial length and diameter in excised lungs, J. Appl. Physiol., 32, (1972)
[9]  
KLINGELE T.G., STAUB N.C., Terminal bronchiole diameter changes with volume in isolated, air-filled lobes of cat lung, J. Appl. Physiol, 30, (1971)
[10]  
MARSHALL R., HOLDEN W.S., Changes in the calibre of the smaller airways in man, Thorax, 18, (1963)