THE MODIFICATION OF ENZYME ELECTRODE PROPERTIES WITH NONCONDUCTING ELECTROPOLYMERIZED FILMS

被引:39
作者
EDDY, S
WARRINER, K
CHRISTIE, I
ASHWORTH, D
PURKISS, C
VADGAMA, P
机构
[1] University of Manchester, Department of Medicine, Clinical Biochemistry, Salford, M6 8HD, Eccles Old Road
基金
英国工程与自然科学研究理事会;
关键词
AMPEROMETRY; ENZYME ENTRAPMENT; GLUCOSE DETERMINATION; MODIFIED ELECTRODES; PHENOLS; SELECTIVITY; SURFACTANT;
D O I
10.1016/0956-5663(95)99222-7
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
Phenol and several phenol derivatives have been electropolymerised on to platinum anodes. The selective properties of the modified electrodes were dependent on the final polymeric structure. Although essentially nonconducting, dual phenolic films could be deposited on electrode surfaces. This was achieved by the initial deposition of a porous polymer formed from, phenol red, followed by the more diffusion limiting film of oxidised phenol. The resulting composite film showed the combined selective characteristics of the two component polymers. Attempts to enhance polymeric film selectivity via the incorporation of charged or neutral surfactants are outlined. The characteristics of glucose oxidase incorporated into (poly)phenol films are discussed.
引用
收藏
页码:831 / 839
页数:9
相关论文
共 26 条
[1]   ELECTROCHEMICAL IMMOBILIZATION OF ENZYMES .1. THEORY [J].
BARTLETT, PN ;
WHITAKER, RG .
JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 1987, 224 (1-2) :27-35
[2]   ELECTROCHEMICAL IMMOBILIZATION OF ENZYMES .2. GLUCOSE-OXIDASE IMMOBILIZED IN POLY-N-METHYLPYRROLE [J].
BARTLETT, PN ;
WHITAKER, RG .
JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 1987, 224 (1-2) :37-48
[3]   ELECTROCHEMICAL IMMOBILIZATION OF ENZYMES .5. MICROELECTRODES FOR THE DETECTION OF GLUCOSE BASED ON GLUCOSE-OXIDASE IMMOBILIZED IN A POLY(PHENOL) FILM [J].
BARTLETT, PN ;
CARUANA, DJ .
ANALYST, 1992, 117 (08) :1287-1292
[4]   ELECTROCHEMICAL IMMOBILIZATION OF ENZYMES .6. MICROELECTRODES FOR THE DETECTION OF L-LACTATE BASED ON FLAVOCYTOCHROME B(2) IMMOBILIZED IN A POLY(PHENOL) FILM [J].
BARTLETT, PN ;
CARUANA, DJ .
ANALYST, 1994, 119 (02) :175-180
[5]  
BARTLETT PN, 1993, J ELECTROANAL CHEM, V362, P1
[6]  
BERGMEYER HU, 1985, METHOD ENZYMAT AN, V7, P299
[7]   MODIFICATION OF ELECTRODE SURFACES WITH OXIDIZED PHENOLS TO CONFER SELECTIVITY TO AMPEROMETRIC BIOSENSORS FOR GLUCOSE DETERMINATION [J].
CHRISTIE, IM ;
VADGAMA, P ;
LLOYD, S .
ANALYTICA CHIMICA ACTA, 1993, 274 (02) :191-199
[8]  
CHRISTIE IM, 1994, CHEM SENS TECHNOL, V5, P131
[9]  
CHRISTIE IM, IN PRESS AMPEROMETRI
[10]   ELECTROCATALYTIC EFFECT OF THE OXIDE FILM AT PT ANODES ON CL RECOMBINATION KINETICS IN CHLORINE EVOLUTION [J].
CONWAY, BE ;
NOVAK, DM .
JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 1979, 99 (02) :133-156