摘要
A detailed study of a commercial zirconia (Y-TZP) aged at 37 degrees C held in Ringer's solution or transplanted in animals or humans is reported. No degradation in strength was found for MOR bars or for hip joint heads subjected to stresses caused by pressing titanium alloy trunnions into the head tapers with loads up to 30 kN. Polished specimens also showed no increase in the monoclinic phase percentage upon aging for 1 year. Small specimens transplanted in animals experience no change in the micro-indentation K-IC toughness value, suggesting no degradation. Zirconia heads recovered after 2 years of human implantation showed no loss of strength. The difference between the excellent performances of this ceramic presented here and other studies can be accounted by the microstructural design and quality of the zirconia. (C) 1994 John Wiley and Sons, Inc.
引用
收藏
页码:619 / 624
页数:6
相关论文
共 23 条
[1]  
CALES B, 1992, 4TH WORLD BIOM C BER
[2]   MECHANICAL-PROPERTIES AND SHORT-TERM INVIVO EVALUATION OF YTTRIUM-OXIDE-PARTIALLY-STABILIZED ZIRCONIA [J].
CHRISTEL, P ;
MEUNIER, A ;
HELLER, M ;
TORRE, JP ;
PEILLE, CN .
JOURNAL OF BIOMEDICAL MATERIALS RESEARCH, 1989, 23 (01) :45-61
[3]  
DINGMAN CA, 1990, 16TH ANN M SOC BIOM
[4]  
DROUIN JM, 1992, 3RD S EUR I BIOM MIC
[5]   INVITRO AGING OF YTTRIA-STABILIZED ZIRCONIA [J].
DRUMMOND, JL .
JOURNAL OF THE AMERICAN CERAMIC SOCIETY, 1989, 72 (04) :675-676
[6]  
FANTOZZI G, 1988, ETUDE COMP MISE POIN
[7]  
GRISS P, 1973, J BIOMED MATER RES S, V4, P453
[8]   EFFECT OF STRESS-INDUCED PHASE-TRANSFORMATION ON PROPERTIES OF POLYCRYSTALLINE ZIRCONIA CONTAINING METASTABLE TETRAGONAL PHASE [J].
GUPTA, TK ;
LANGE, FF ;
BECHTOLD, JH .
JOURNAL OF MATERIALS SCIENCE, 1978, 13 (07) :1464-1470
[9]   LOW WEAR RATE OF UHMWPE AGAINST ZIRCONIA CERAMIC (Y-PSZ) IN COMPARISON TO ALUMINA CERAMIC AND SUS 316L ALLOY [J].
KUMAR, P ;
OKA, M ;
IKEUCHI, K ;
SHIMIZU, K ;
YAMAMURO, T ;
OKUMURA, H ;
KOTOURA, Y .
JOURNAL OF BIOMEDICAL MATERIALS RESEARCH, 1991, 25 (07) :813-828
[10]  
LANGLAIS F, 1983, CAHIERS ENSEIGNEMENT, V20, P14