RATIONALE AND OBJECTIVES. We preliminarily investigated whether dynamic contrast bolus computed tomography (CT) could be used to measure glomerular filtration rate. METHOD. After bolus intravenous contrast injection, rapid sequence CT scans were performed at a fixed level through the kidneys and aorta in three patients with biochemically normal renal function who underwent routine CT examination. A mathematical technique developed initially for positron-emission tomography was adapted for analysis of the CT data for measurement of renal contrast clearance per unit renal volume and of the fraction of renal tissue occupied by blood volume. RESULTS. Renal blood volumes in the 3 patients were 0.28, 0.29, and 0.31 of total renal volume, respectively, and the corresponding contrast clearances were 0.44, 0.41, and 0.35 mL per min per mL of renal tissue. CONCLUSIONS. This preliminary study in normal patients demonstrates that dynamic contrast CT might be developed for clinical physiological renal studies. Further work to validate the accuracy and reliability of the method in comparison with established isotope methods is suggested.
引用
收藏
页码:1039 / 1042
页数:4
相关论文
共 10 条
[1]   USE OF UROGRAPHIC CONTRAST-MEDIA TO DETERMINE GLOMERULAR-FILTRATION RATE - DETERMINING THE GLOMERULAR-FILTRATION RATE OF EACH KIDNEY WITH COMPUTED-TOMOGRAPHY AND SCINTIGRAPHY [J].
ALMEN, T ;
BERGQUIST, D ;
FRENNBY, B ;
HELLSTEN, S ;
LILJA, B ;
NYMAN, U ;
STERNER, G ;
TORNQUIST, C .
INVESTIGATIVE RADIOLOGY, 1991, 26 :S72-S74
[2]  
Crone C., 1984, HDB PHYSL CARDIOVASC, VIV, P411
[3]  
HAWKINS RA, 1992, J NUCL MED, V33, P633
[4]   MEASUREMENT OF TISSUE PERFUSION BY DYNAMIC COMPUTED-TOMOGRAPHY [J].
MILES, KA .
BRITISH JOURNAL OF RADIOLOGY, 1991, 64 (761) :409-412
[5]   DYNAMIC COMPUTED-TOMOGRAPHY OF THE BRAIN - TECHNIQUES, DATA-ANALYSIS, AND APPLICATIONS [J].
NORMAN, D ;
AXEL, L ;
BERNINGER, WH ;
EDWARDS, MS ;
CANN, CE ;
REDINGTON, RW ;
COX, L .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1981, 136 (04) :759-770
[6]   GRAPHICAL EVALUATION OF BLOOD-TO-BRAIN TRANSFER CONSTANTS FROM MULTIPLE-TIME UPTAKE DATA [J].
PATLAK, CS ;
BLASBERG, RG ;
FENSTERMACHER, JD .
JOURNAL OF CEREBRAL BLOOD FLOW AND METABOLISM, 1983, 3 (01) :1-7
[7]   MEASUREMENT OF MICROVASCULAR PERMEABILITY TO SMALL SOLUTES IN MAN - LIMITATIONS OF THE TECHNIQUE [J].
PETERS, AM .
CARDIOVASCULAR RESEARCH, 1990, 24 (06) :504-509
[8]   APPROPRIATE SELECTION OF BACKGROUND FOR TC-99M-DTPA RENOGRAPHY [J].
PETERS, AM ;
GEORGE, P ;
BALLARDIE, F ;
GORDON, I ;
TODDPOKROPEK, A .
NUCLEAR MEDICINE COMMUNICATIONS, 1988, 9 (12) :973-985
[9]   TC-99M-DTPA GAMMA-CAMERA RENOGRAPHY - NORMAL VALUES AND RAPID-DETERMINATION OF SINGLE-KIDNEY GLOMERULAR-FILTRATION RATE [J].
REHLING, M ;
MOLLER, ML ;
LUND, JO ;
JENSEN, KB ;
THAMDRUP, B ;
TRAPJENSEN, J .
EUROPEAN JOURNAL OF NUCLEAR MEDICINE, 1985, 11 (01) :1-6
[10]   The regulation of renal activity VIII. The relation between the rate of urea excretion and the size of the kidney [J].
Taylor, FB ;
Drury, DR ;
Addis, T .
AMERICAN JOURNAL OF PHYSIOLOGY, 1923, 65 (01) :55-61