SAMPLE-SIZE CALCULATIONS FOR OPHTHALMOLOGIC STUDIES

被引:28
作者
GAUDERMAN, WJ
BARLOW, WE
机构
[1] UNIV WASHINGTON,DEPT BIOSTAT,SEATTLE,WA 98195
[2] UNIV WASHINGTON,DEPT OPHTHALMOL,SEATTLE,WA 98195
[3] CTR HLTH STUDIES,HLTH COOPERAT GRP,SEATTLE,WA
关键词
D O I
10.1001/archopht.1992.01080170112036
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Sample size calculations are shown for some common ophthalmologic study designs in which two treatments are to be compared. Included are the following three designs: 1, only one eye per subject; 2, both eyes, with each eye assigned to a different treatment; and 3, both eyes undergoing a common treatment. Continuous and binary outcomes are considered. The correlation between eyes is accounted for in the computations using a simple correction factor. For design 3, the formulas allow for a mixture of single-eye and double-eye eligible subjects. A computer program that performs the calculations is available.
引用
收藏
页码:690 / 692
页数:3
相关论文
共 9 条
[1]   SAMPLE-SIZE FOR TESTING DIFFERENCES IN PROPORTIONS FOR THE PAIRED-SAMPLE DESIGN [J].
CONNOR, RJ .
BIOMETRICS, 1987, 43 (01) :207-211
[2]   STATISTICAL-METHODS IN OPHTHALMOLOGY - AN ADJUSTED CHI-SQUARE APPROACH [J].
DONNER, A .
BIOMETRICS, 1989, 45 (02) :605-611
[3]   RANDOMIZATION BY CLUSTER - SAMPLE-SIZE REQUIREMENTS AND ANALYSIS [J].
DONNER, A ;
BIRKETT, N ;
BUCK, C .
AMERICAN JOURNAL OF EPIDEMIOLOGY, 1981, 114 (06) :906-914
[5]  
PALMER EA, 1986, PEDIATRICS, V77, P428
[7]   SIGNIFICANCE TESTING FOR CORRELATED BINARY OUTCOME DATA [J].
ROSNER, B ;
MILTON, RC .
BIOMETRICS, 1988, 44 (02) :505-512
[8]  
SEIGEL D, 1987, ARCH OPHTHALMOL-CHIC, V105, P185
[9]  
Zar J, 1984, BIOSTAT ANAL, V2nd