RATE-MODULATED PACING

被引:21
作者
FURMAN, S [1 ]
机构
[1] YESHIVA UNIV ALBERT EINSTEIN COLL MED,BRONX,NY 10461
关键词
D O I
10.1161/01.CIR.82.4.1081
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
The primary role of cardiac rate in adapting cardiac output to changing physiological needs has been more clearly recognized in recent years. Previously, the rate of cardiac stimulation had been determined either at pacemaker manufacture, by programming a single rate, or by sensing the atrium. More recently, sensing another physiological or nonphysiological function that changes in response to body need has become possible. Exercise changes blood oxygen saturation, central venous pH, central venous temperature, minute ventilation and respiratory rate, stroke volume, circulating catecholamines, QT interval, evoked endocardial response to a stimulus, and the mechanics of myocardial contraction. Some sensors respond to muscle work but not to intellectual effort or emotion. Pacemaker-based sensors of physiological function or activity allow a change in cardiac stimulation rate in response to need. Whichever sensor is used, increases in ventricular rate during exercise regularly produce a cardiac output response. Single-chamber, rate-modulated pacemakers in atrium or ventricle and dual-chamber devices are now implanted on a widespread basis. These drive the atrium, the ventricle, or both, sensing or pacing the atrium at a rate determined by the sensor.
引用
收藏
页码:1081 / 1094
页数:14
相关论文
共 83 条
[1]   3 CASES OF HYPOTENSION AND SYNCOPE WITH VENTRICULAR PACING - POSSIBLE ROLE OF ATRIAL REFLEXES [J].
ALICANDRI, C ;
FOUAD, FM ;
TARAZI, RC ;
CASTLE, L ;
MORANT, V .
AMERICAN JOURNAL OF CARDIOLOGY, 1978, 42 (01) :137-142
[2]   MEASUREMENT OF RIGHT VENTRICULAR BLOOD TEMPERATURE DURING EXERCISE AS A MEANS OF RATE CONTROL IN PHYSIOLOGICAL PACEMAKERS [J].
ALT, E ;
HIRGSTETTER, C ;
HEINZ, M ;
THERES, H .
PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 1986, 9 (06) :970-977
[3]   RATE CONTROL OF PHYSIOLOGICAL PACEMAKERS BY CENTRAL VENOUS-BLOOD TEMPERATURE [J].
ALT, E ;
HIRGSTETTER, C ;
HEINZ, M ;
BLOMER, H .
CIRCULATION, 1986, 73 (06) :1206-1212
[4]   A NEW RATE-MODULATED PACEMAKER SYSTEM OPTIMIZED BY COMBINATION OF 2 SENSORS [J].
ALT, E ;
THERES, H ;
HEINZ, M ;
MATULA, M ;
THILO, R ;
BLOMER, H .
PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 1988, 11 (08) :1119-1129
[5]   AUTODIAGNOSTIC PACEMAKER [J].
AUERBACH, AA ;
FURMAN, S .
PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 1979, 2 (01) :58-68
[6]   THE PACEMAKER SYNDROME [J].
AUSUBEL, K ;
FURMAN, S .
ANNALS OF INTERNAL MEDICINE, 1985, 103 (03) :420-429
[7]  
Bazett HC, 1920, HEART-J STUD CIRC, V7, P353
[9]   SENSOR-TRIGGERED, RATE-VARIABLE CARDIAC PACING - CURRENT TECHNOLOGIES AND CLINICAL IMPLICATIONS [J].
BENDITT, DG ;
MILSTEIN, S ;
BUETIKOFER, J ;
GORNICK, CC ;
MIANULLI, M ;
FETTER, J .
ANNALS OF INTERNAL MEDICINE, 1987, 107 (05) :714-724
[10]   SINGLE-CHAMBER CARDIAC PACING WITH ACTIVITY-INITIATED CHRONOTROPIC RESPONSE - EVALUATION BY CARDIOPULMONARY EXERCISE TESTING [J].
BENDITT, DG ;
MIANULLI, M ;
FETTER, J ;
BENSON, DW ;
DUNNIGAN, A ;
MOLINA, E ;
GORNICK, CC ;
ALMQUIST, A .
CIRCULATION, 1987, 75 (01) :184-191