EFFECTS OF STANDARD MITRAL-VALVE REPLACEMENT ON LEFT-VENTRICULAR FUNCTION

被引:22
作者
HARPOLE, DH
RANKIN, JS
WOLFE, WG
CLEMENTS, FM
VANTRIGT, P
YOUNG, WG
JONES, RH
机构
[1] DUKE UNIV, MED CTR, DEPT SURG, POB 3851, DURHAM, NC 27710 USA
[2] DUKE UNIV, MED CTR, DEPT ANESTHESIOL, DURHAM, NC 27710 USA
关键词
D O I
10.1016/0003-4975(90)90858-4
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Recent studies have suggested that excision of the mitral valve apparatus during mitral valve replacement impairs left ventricular performance. However, functional measurements in humans have been difficult to obtain in a load-independent fashion. To investigate this concept, 12 patients (mean age, 65 ± 8 years; mean New York Heart Association functional class, 3.3 ± 0.7) with 4+ mitral regurgitation (n = 8) or mitral stenosis (valve area, 1.2 ± 0.2 cm2) (n = 4) underwent prosthetic valve replacement using crystalloid cardioplegia. No patient required therapeutic inotropic support, every patient had at least the anterior mitral leaflet excised, and paced heart rate was maintained constant throughout. Left ventricular volume was measured with radionuclide angiocardiography, left ventricular pressure with a 3F micromanometer, and left ventricular wall volume with two-dimensional transesophageal echocardiography. Left ventricular preload was varied over a mean enddiastolic pressure range of 9 to 20 mm Hg and an end-diastolic volume range of 134 to 170 mL to generate four to five steady-state pressure-volume loops before and ten minutes after cardiopulmonary bypass. Left ventricular performance was estimated with the stroke work/end-diastolic volume relationship, which is insensitive to load. After bypass, no significant change (p > 0.1) was noted in wall volume for patients with mitral regurgitation or mitral stenosis (175 ± 68 to 189 ± 63 mL/m2 and 130 ± 22 to 127 ± 19 mL/m2, respectively). The stroke work/end-diastolic volume relationships were highly linear before and after bypass with a mean linear regression coefficient of 0.96 ± 0.03, and the slope and x-intercept were not changed after bypass (p > 0.1). These data suggest that partial excision of the mitral apparatus does not significantly impair left ventricular performance during the early period after routine valve replacement. © 1990.
引用
收藏
页码:866 / 874
页数:9
相关论文
共 30 条
[1]  
ANGELL WW, 1987, J THORAC CARDIOV SUR, V93, P665
[2]  
BONCHEK LI, 1984, J THORAC CARDIOV SUR, V88, P122
[3]  
CARPENTIER A, 1971, J THORAC CARDIOV SUR, V61, P1
[4]  
DAVID TE, 1984, J THORAC CARDIOV SUR, V88, P718
[5]  
DAVID TE, 1983, CIRCULATION, V68, P76
[6]   MITRAL-VALVE REPLACEMENT WITH PRESERVATION OF CHORDAE TENDINAE - RATIONALE AND TECHNICAL CONSIDERATIONS [J].
DAVID, TE .
ANNALS OF THORACIC SURGERY, 1986, 41 (06) :680-682
[7]  
DAVID TE, 1986, CIRCULATION, V74, P116
[8]   CORRELATION OF ECHOCARDIOGRAPHIC WALL STRESS AND LEFT-VENTRICULAR PRESSURE AND FUNCTION IN AORTIC-STENOSIS [J].
DEPACE, NL ;
REN, JF ;
ISKANDRIAN, AS ;
KOTLER, MN ;
HAKKI, AH ;
SEGAL, BL .
CIRCULATION, 1983, 67 (04) :854-859
[9]   INVIVO ESTIMATION OF LEFT-VENTRICULAR WALL VOLUME IN VOLUME-OVERLOADED CANINE HEARTS [J].
FENELEY, MP ;
GAYNOR, JW ;
MAIER, GW ;
GALL, SA ;
KISSLO, JA ;
RANKIN, JS .
AMERICAN JOURNAL OF PHYSIOLOGY, 1988, 255 (06) :H1399-H1404
[10]   LINEARITY OF THE FRANK-STARLING RELATIONSHIP IN THE INTACT HEART - THE CONCEPT OF PRELOAD RECRUITABLE STROKE WORK [J].
GLOWER, DD ;
SPRATT, JA ;
SNOW, ND ;
KABAS, JS ;
DAVIS, JW ;
OLSEN, CO ;
TYSON, GS ;
SABISTON, DC ;
RANKIN, JS .
CIRCULATION, 1985, 71 (05) :994-1009