DEVELOPMENT OF FRP COMPOSITE STRUCTURAL BIOMATERIALS - ULTIMATE STRENGTH OF THE FIBER MATRIX INTERFACIAL BOND IN INVIVO SIMULATED ENVIRONMENTS

被引:21
作者
LATOUR, RA
BLACK, J
机构
[1] Department of Bioengineering, Clemson University, Clemson, South Carolina
来源
JOURNAL OF BIOMEDICAL MATERIALS RESEARCH | 1992年 / 26卷 / 05期
关键词
D O I
10.1002/jbm.820260504
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Fiber reinforced polymer (FRP) composites are being developed as alternatives to metals for structural orthopedic implant applications. FRP composite fracture behavior and environmental interactions are distinctly different from those which occur in metals. These differences must be accounted for in the design and evaluation of implant performance. Fiber/matrix interfacial bond strength in a FRP composite is known to strongly influence fracture behavior. The interfacial bond strength of four candidate fiber/matrix combinations (carbon fiber/polycarbonate, carbon fiber/polysulfone, polyaramid fiber/polycarbonate, polyaramid fiber/polysulfone) were investigated at 37-degrees-C in dry and in vivo simulated (saline, exudate) environments. Ultimate bond strength was measured by a single fiber-microdroplet pull-out test. Dry bond strengths were significantly decreased following exposure to either saline or exudate with bond strength loss being approximately equal in both the saline and exudate. Bond strength loss is attributed to the diffusion of water and/or salt ions into the sample and their interaction with interfacial bonding. Because bond degradation is dependent upon diffusion, diffusional equilibrium must be obtained in composite test samples before the full effect of the test environment upon composite mechanical behavior can be determined.
引用
收藏
页码:593 / 606
页数:14
相关论文
共 32 条
[1]  
ALTOUR RA, 1989, THESIS U PENNSYLVANI
[2]  
BERG M, 1991, ADV COMPOSITE MATERI, V231, P3
[3]  
Berlin AA, 1986, PRINCIPLES POLYM COM
[4]   FAILURE OF DESICCATOR STORAGE TO MAINTAIN INTERFACIAL BOND STRENGTH IN SOME THERMOPLASTIC FIBER SYSTEMS [J].
BLACK, J ;
LATOUR, RA ;
MILLER, B .
JOURNAL OF ADHESION SCIENCE AND TECHNOLOGY, 1989, 3 (01) :65-67
[5]   COMPENDIUM OF NORMAL BLOOD VALUES OF LABORATORY ANIMALS WITH INDICATION OF VARIATIONS .I. RANDOM-SEXED POPULATIONS OF SMALL ANIMALS [J].
BURNS, KF ;
DELANNOY, CW .
TOXICOLOGY AND APPLIED PHARMACOLOGY, 1966, 8 (03) :429-&
[6]   THE GLASS-FIBER POLYMER INTERFACE .1. THEORETICAL CONSIDERATION FOR SINGLE FIBER PULL-OUT TESTS [J].
CHUA, PS ;
PIGGOTT, MR .
COMPOSITES SCIENCE AND TECHNOLOGY, 1985, 22 (01) :33-42
[7]  
DAVIDSON JA, 1987, J COMPOS TECH RES, V9, P151
[8]  
DRZAL LT, 1990, CONTROLLED INTERPHASES IN COMPOSITE MATERIALS, P309
[9]   THE SOLUBILITY AND DIFFUSION OF WATER IN POLY(ARYL-ETHER-ETHER-KETONE) (PEEK) [J].
GRAYSON, MA ;
WOLF, CJ .
JOURNAL OF POLYMER SCIENCE PART B-POLYMER PHYSICS, 1987, 25 (01) :31-41
[10]  
HENDERSON JD, 1987, J BIOMED MATER RES, V21, P59, DOI 10.1002/jbm.820210110