BIMETAL ANODE WITH TUNGSTEN OR RHODIUM - COMPARATIVE-STUDIES ON IMAGE QUALITY AND RADIATION EXPOSURE IN SCREEN-FILM MAMMOGRAPHY

被引:3
作者
FUNKE, M [1 ]
HERMANN, KP [1 ]
BREITER, N [1 ]
MORITZ, J [1 ]
MULLER, D [1 ]
GRABBE, E [1 ]
机构
[1] UNIV GOTTINGEN,MED PHYS & BIOPHYS ABT,D-37075 GOTTINGEN,GERMANY
来源
FORTSCHRITTE AUF DEM GEBIETE DER RONTGENSTRAHLEN UND DER NEUEN BILDGEBENDEN VERFAHREN | 1995年 / 163卷 / 05期
关键词
MAMMOGRAPHY; BIMETAL ANODE; CONTRAST; RADIATION EXPOSURE;
D O I
10.1055/s-2007-1016014
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: The impact of different anode materials (tungsten and rhodium) on spatial resolution, image contrast and radiation exposure was studied. Materials and methods: Two mammographic systems providing bimetal x-ray tubes (Mo/W and Mo/Rh) were compared by imaging a breast radiography phantom with additional acrylic plates from 3 to 8 cm thickness. Spatial resolution was evaluated using a line bar pattern. Image contrast was assessed by measuring the ratio of optical densities in a acrylic step-wedge. The entrance dose was measured. with a low energy ionisation chamber. Results: The spatial resolution was about 13 lp/mm regardless of the beam quality The image contrast depended substantially on the thickness. A similar image contrast was found with Mo/Mo, Mo/Rh and Rh/Rh for simulated breast thicknesses of 4 to 6 cm and with Rh/Rh and W/Rh for 7 cm. In comparison to Mo/Mo the dose reduction was significant for Mo/Ph (35 %), Rh/Rh (50 %) and W/Rh (60 %). Conclusions: Bimetal x-ray tubes provide optimal conditions for screen film mammography of both normal and dense breasts, allowing good contrast and dose reduction by using the adequate anode/filter-combination.
引用
收藏
页码:388 / 394
页数:7
相关论文
共 12 条
[1]   MONTE-CARLO CALCULATION OF CONVERSION FACTORS FOR THE ESTIMATION OF MEAN GLANDULAR BREAST DOSE [J].
DANCE, DR .
PHYSICS IN MEDICINE AND BIOLOGY, 1990, 35 (09) :1211-1219
[2]   INFLUENCE OF ANODE AND FILTER MATERIAL ON IMAGE QUALITY AND GLANDULAR DOSE FOR SCREEN FILM MAMMOGRAPHY [J].
DESPONDS, L ;
DEPEURSINGE, C ;
GRECESCU, M ;
HESSLER, C ;
SAMIRI, A ;
VALLEY, JF .
PHYSICS IN MEDICINE AND BIOLOGY, 1991, 36 (09) :1165-1182
[3]   EFFECT OF X-RAY-SPECTRA FROM MOLYBDENUM AND TUNGSTEN TARGET TUBES ON IMAGE QUALITY IN MAMMOGRAPHY [J].
HAUS, AG ;
METZ, CE ;
CHILES, JT ;
ROSSMANN, K .
RADIOLOGY, 1976, 118 (03) :705-709
[4]   NEW MAMMOGRAPHY SCREE FILM COMBINATIONS - IMAGING CHARACTERISTICS AND RADIATION-DOSE [J].
KIMMESMITH, C ;
BASSETT, LW ;
GOLD, RH ;
ZHEUTLIN, J ;
GORNBEIN, JA .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1990, 154 (04) :713-719
[5]  
KLAUSZ R, 1989, RADIOLOGY P, V173, P395
[6]  
KUCHLER M, 1993, ROFO FORTSCHR RONTG, V159, P34
[7]  
Minski M, 1988, Rofo, V148, P437, DOI 10.1055/s-2008-1048226
[8]  
ROTHENBERG LN, 1993, TECHNICAL ASPECTS BR, P111
[9]  
Sabel M, 1981, Rofo, V134, P250, DOI 10.1055/s-2008-1056348
[10]  
Schule E, 1981, Rofo, V135, P204, DOI 10.1055/s-2008-1056860