POSITIVE PRESSURE VENTILATION USING A SEMICLOSED SYSTEM - A REASSESSMENT

被引:9
作者
MARSHALL, M
HENDERSON, GA
机构
关键词
D O I
10.1093/bja/40.4.265
中图分类号
R614 [麻醉学];
学科分类号
100217 ;
摘要
Summary: The use of a semiclosed system (the Magill attachment) for positive pressure breathing was investigated. Various patterns of ventilation were used and their effects assessed by serial measurement of the arterial carbon dioxide. It was found that this could be kept within limits comparable to those found during normal sleep using a flow of fresh gases as low as 5 l./min. This result was most easily achieved if the tidal volume were large (more than 1 1. for the average adult). Other incidental findings are discussed and it is concluded that semiclosed systems provide a safe and economical method for maintaining ventilation when special equipment is not available. © 1968 John Sherratt and Son Ltd.
引用
收藏
页码:265 / +
页数:1
相关论文
共 9 条
[3]  
HOLMDAHL MH, 1956, ACTA CHIR SCAND S21
[4]  
HUNTER AR, 1963, RECENT ADVANCES ANAE, P286
[5]   POSTHYPERVENTILATION APNEA IN AWAKE DOGS DURING METABOLIC ACIDOSIS AND HYPOXIA [J].
MITCHELL, RA ;
BAINTON, CR ;
EDELIST, G .
JOURNAL OF APPLIED PHYSIOLOGY, 1966, 21 (04) :1363-&
[6]  
PARKHOUSE J, 1963, RECENT ADVANCES ANAE, P8
[7]   ALVEOLAR GAS TENSIONS, PULMONARY VENTILATION AND BLOOD PH DURING PHYSIOLOGIC SLEEP IN NORMAL SUBJECTS [J].
ROBIN, ED ;
WHALEY, RD ;
CRUMP, CH ;
TRAVIS, DM .
JOURNAL OF CLINICAL INVESTIGATION, 1958, 37 (07) :981-989
[8]   REBREATHING DURING CONTROLLED RESPIRATION WITH THE MAGILL ATTACHMENT [J].
SYKES, MK .
BRITISH JOURNAL OF ANAESTHESIA, 1959, 31 (06) :247-257
[9]   REBREATHING DURING CONTROLLED RESPIRATION WITH VARIOUS SEMICLOSED ANAESTHETIC SYSTEMS [J].
WATERS, DJ ;
MAPLESON, WW .
BRITISH JOURNAL OF ANAESTHESIA, 1961, 33 (08) :374-&