INFLUENCE OF INITIAL FLAW SIZE ON CRACK-GROWTH IN AIR-TEMPERED PORCELAIN

被引:17
作者
ANUSAVICE, KJ
GRAY, A
SHEN, C
机构
[1] Department of Dental Biomaterials, College of Dentistry, University of Florida, Gainesville
关键词
D O I
10.1177/00220345910700020701
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Tempering of dental porcelain by forced convective cooling in air has been shown previously to inhibit the sizes of cracks induced in porcelain surfaces. However, the depth of compressive stress that is produced by tempering of feldspathic porcelain has not been determined. It can be assumed that the potential of tempered specimens to inhibit crack formation is reduced as the flaw size exceeds some critical value, since the compressive stress decreases with distance from the surface. The objective of this study was to test the hypothesis that the effectiveness of tempering stress in porcelain decreases with the increasing size of initial surface flaws. Body porcelain discs, 16 mm in diameter and 2 mm in thickness, were tempered (T) by forced convective cooling in air from an initial temperature of 982-degrees-C at a pressure of 0.34 MPa for 90 s. Non-tempered control discs (NT) were slowly cooled by termination of power to the furnace. The half crack-lengths (c) of surface cracks induced by a Vickers microhardness indenter at loads ranging from 2.0 to 39.2 N were determined initially and over a period of 24 h. The initial half crack-lengths, c(o), for the tempered specimens were significantly smaller (p < 0.05) than the corresponding values for the slow-cooled specimens. The mean value of the stress corrosion susceptibility coefficient (n), which is inversely related to the slope of log crack size vs. log time, was only slightly smaller for the NT specimen groups (15.3), compared with the mean value for the T groups (17.1). These results indicate that tempering stress can effectively inhibit the initial sizes of half-penny cracks with initial depths of at least 100-mu-m. However, in tempered specimens, the growth rate of initial cracks, which varied in length from 21.4-mu-m to 76.1-mu-m, was relatively insensitive to the compressive stress (78.1 MPa) produced by tempering.
引用
收藏
页码:131 / 136
页数:6
相关论文
共 15 条
[1]   A CRITICAL-EVALUATION OF INDENTATION TECHNIQUES FOR MEASURING FRACTURE-TOUGHNESS .1. DIRECT CRACK MEASUREMENTS [J].
ANSTIS, GR ;
CHANTIKUL, P ;
LAWN, BR ;
MARSHALL, DB .
JOURNAL OF THE AMERICAN CERAMIC SOCIETY, 1981, 64 (09) :533-538
[2]   INFLUENCE OF TEMPERING AND CONTRACTION MISMATCH ON CRACK DEVELOPMENT IN CERAMIC SURFACES [J].
ANUSAVICE, KJ ;
DEHOFF, PH ;
HOJJATIE, B ;
GRAY, A .
JOURNAL OF DENTAL RESEARCH, 1989, 68 (07) :1182-1187
[3]  
ANUSAVICE KJ, 1989, J DENT RES, V68, P324
[4]  
CREYKE WEC, 1968, BRIT CERAM T, V67, P339
[5]   TEMPERING STRESSES IN FELDSPATHIC PORCELAIN [J].
DEHOFF, PH ;
ANUSAVICE, KJ .
JOURNAL OF DENTAL RESEARCH, 1989, 68 (02) :134-138
[6]   TEMPERING GLASS WITH MODULATED COOLING SCHEDULES [J].
GARDON, R .
JOURNAL OF THE AMERICAN CERAMIC SOCIETY, 1988, 71 (10) :876-878
[7]  
Gardon R., 1980, GLASS SCI TECHNOL, P145
[8]  
GUPTA PK, 1981, J AM CERAM SOC, V64, pC112, DOI 10.1111/j.1151-2916.1981.tb09909.x
[9]  
HOJJATIE B, 1989, J DENT RES, V68, P324
[10]  
LAWN BR, 1977, PHYS CHEM GLASSES, V18, P7