DOPPLER ENHANCEMENT WITH SH-U-508A IN MULTIPLE VASCULAR REGIONS

被引:88
作者
SCHWARZ, KQ
BECHER, H
SCHIMPFKY, C
VORWERK, D
BOGDAHN, U
SCHLIEF, R
机构
[1] CTR BIOMED ULTRASOUND,ROCHESTER,NY
[2] UNIV BONN,MED CLIN,BONN,GERMANY
[3] SCHERING AG,DIV CLIN RES,W-1000 BERLIN,GERMANY
[4] CLIN RADIOL DIAGNOST,AACHEN,GERMANY
[5] UNIV WURZBURG,DEPT NEUROL,W-8700 WURZBURG,GERMANY
关键词
CONTRAST MATERIAL; ULTRASOUND; (US); CONTRAST MEDIA; DOPPLER STUDIES; TECHNOLOGY;
D O I
10.1148/radiology.193.1.7916468
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
PURPOSE: To determine the magnitude and duration of peripheral vascular and cardiac Doppler signal enhancement after intravenous administration of contrast agent SH U 508A. MATERIALS AND METHODS: Suboptimal cardiac or peripheral vascular Doppler examinations were evaluated. A total of 75 intravenous bolus injections were made in 30 patients. Spectral audio Doppler intensity was measured throughout the duration of contrast effect. RESULTS: No clinically relevant adverse effects were noted, and Doppler enhancement was apparent in all cases. The diagnostic confidence of the investigators when scored before and after Doppler enhancement improved from 35% to 91% (P < .05). Doppler intensity increased more than 16 dB in all vascular regions investigated (P < .05). The contrast effect lasted for more than 120 seconds in the peripheral vascular and cardiac groups at equivalent doses. CONCLUSION: Intravenously administered SH U 508A is effective in markedly increasing cardiac, femoral arterial, and transcranial (cerebral arterial) Doppler signal intensity. The effect improves the clinical diagnostic confidence in eases of suboptimal unenhanced Doppler examinations.
引用
收藏
页码:195 / 201
页数:7
相关论文
共 16 条
[1]   CONTRAST-ENHANCED TRANSCRANIAL COLOR-CODED REAL-TIME SONOGRAPHY - RESULTS OF A PHASE-2 STUDY [J].
BOGDAHN, U ;
BECKER, G ;
SCHLIEF, R ;
REDDIG, J ;
HASSEL, W .
STROKE, 1993, 24 (05) :676-684
[2]  
BOMMER W, 1981, CIRCULATION, V4, P203
[3]  
BOMMER WJ, 1979, CIRCULATION, V60, P17
[4]   CONTRAST ECHOCARDIOGRAPHIC MAPPING OF COLLATERALIZED MYOCARDIUM IN HUMANS BEFORE AND AFTER CORONARY ANGIOPLASTY [J].
GRILL, HP ;
BRINKER, JA ;
TAUBE, JC ;
WALFORD, GD ;
MIDEI, MG ;
FLAHERTY, JT ;
WEISS, JL .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1990, 16 (07) :1594-1600
[5]  
KAUL S, 1990, AM J CARDIAC IMAGING, V4, P38
[6]   MYOCARDIAL WASHOUT OF SONICATED IOPAMIDOL REFLECTS CORONARY BLOOD-FLOW IN THE ABSENCE OF AUTOREGULATION [J].
ROVAI, D ;
GHELARDINI, G ;
LOMBARDI, M ;
TRIVELLA, MG ;
NEVOLA, E ;
TADDEI, L ;
MICHELASSI, C ;
DISTANTE, A ;
DEMARIA, AN ;
LABBATE, A .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1992, 20 (06) :1417-1424
[7]  
RUZICKA J, 1988, FLOW INJECTION ANAL, P54
[8]  
SCHLIEF R, 1991, CURR OPIN RADIOL, V3, P198
[9]  
SCHLIEF R, 1990, ECHOCARDIOGR-J CARD, V7, P1
[10]   VOLUMETRIC ARTERIAL FLOW QUANTIFICATION USING ECHO CONTRAST - AN IN-VITRO COMPARISON OF 3 ULTRASONIC INTENSITY METHODS - RADIO-FREQUENCY, VIDEO AND DOPPLER [J].
SCHWARZ, KQ ;
BEZANTE, GP ;
CHEN, XC ;
MOTTLEY, JG ;
SCHLIEF, R .
ULTRASOUND IN MEDICINE AND BIOLOGY, 1993, 19 (06) :447-460