IN-VITRO PROPERTIES OF PRESSURIZED METERED-DOSE INHALERS WITH AND WITHOUT SPACER DEVICES

被引:42
作者
BERG, E
机构
[1] Astra Draco AB, Pharmaceutical & Analytical, Research & Development, S-221 00 Lund
来源
JOURNAL OF AEROSOL MEDICINE-DEPOSITION CLEARANCE AND EFFECTS IN THE LUNG | 1995年 / 8卷
关键词
PMDIS; SPACER DEVICES; FINE PARTICLE DOSE; LUNG DEPOSITION;
D O I
10.1089/jam.1995.8.Suppl_3.S-3
中图分类号
R1 [预防医学、卫生学];
学科分类号
1004 ; 120402 ;
摘要
Pressurized metered dose inhalers (pMDIs) have been used for the administration of drugs to patients with asthma since the late 1950s. However, it is only during the last few years that attention has been paid to how they work in detail. Studies have shown that the first dose, after the inhaler has been at rest for some hours, can be very variable. For suspension formulations, shaking the inhaler before actuation is important, since omitting shaking will affect the dose uniformity. The addition of a spacer device may increase the variability of the available dose. Factors affecting the available dose are, the electrostatic charge on the walls of the spacer device, the volume of the spacer device and the choice of material for the spacer device. Moreover, the fine particle dose, a measure of the effective deposition of inhaled drug in the airways, has been shown to be greater with a pMDI and a spacer device in comparison with a pMDI alone and is dependent on the choice of impactor inlet.
引用
收藏
页码:S3 / S11
页数:9
相关论文
共 8 条
[1]  
BARRY P.W., O'CALLAGHAN C., Poor output of salbutamol from a spacer device. Effect of spacer static charge and multiple actuations, Thorax, 44, (1994)
[2]  
BARRY P.W., ROBERTSON C.F., O'CALLAGHAN C., Optimum use of a spacer device, Arch. Dis. Child., 69, pp. 693-694, (1993)
[3]  
BYRON P.R., Aerosol formulation, generation and delivery using metered systems, Respiratory drug delivery, (1990)
[4]  
CYR T., GRAHAM S.J., LI R.K.Y., LOVERING E.G., Low first-spray drug content in albuterol metered-dose inhalers, Pharm. Res., 8, pp. 658-660, (1991)
[5]  
EVERARD M.L., Drug delivery from holding chambers with attached face mask, Arch. Dis. Child., 67, pp. 580-585, (1992)
[6]  
MOREN F., Aerosol dosage forms and formulations, Aerosols in Medicine: Principles, Diagnosis and Therapy, pp. 321-350, (1993)
[7]  
O'CALLAGHAN C., CANT M., ROBERTSON C., Delivery of beclomethasone dipropionate from a spacer device: what dose is available for inhalation, Thorax, 49, pp. 961-964, (1994)
[8]  
SWIFT D.L., Apparatus and method for measuring regional distribution of therapeutic aerosols and comparing delivery systems, J. Aerosol Sci., 23, pp. S495-S498, (1992)