INTRAVENOUS CONTRAST ECHOCARDIOGRAPHY WITH USE OF SONICATED ALBUMIN IN HUMANS - SYSTOLIC DISAPPEARANCE OF LEFT-VENTRICULAR CONTRAST AFTER TRANSPULMONARY TRANSMISSION

被引:64
作者
SHAPIRO, JR
REISNER, SA
LICHTENBERG, GS
MELTZER, RS
机构
[1] UNIV ROCHESTER,MED CTR,DEPT ANESTHESIOL,BOX 679,ROCHESTER,NY 14642
[2] UNIV ROCHESTER,MED CTR,CTR BIOMED ULTRASOUND,ROCHESTER,NY 14642
[3] UNIV ROCHESTER,MED CTR,DEPT MED,ROCHESTER,NY 14642
关键词
D O I
10.1016/0735-1097(90)90308-C
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
The transmission of echocardiographic contrast medium and the cyclic changes in left ventricular videodensity during transpulmonary contrast echocardiography were investigated in nine adult volunteers with the use of intravenous injections of sonicated albumin (microbubble size 5.2 +/- 2.6-mu-m). Right and left ventricular and myocardial contrast were quantitated by videodensitometric analysis. The injections caused no symptoms, and no hemodynamic or electrocardiographic changes were observed. All injections resulted in right ventricular contrast. Mean peak right ventricular videodensity was 75 +/- 48 at end-diastole and 61 +/- 36 gray scale U/pixel at end-diastole (p < 0.05). Seventy-eight percent of injections resulted in left ventricular contrast with a mean peak videodensity of 21 +/- 33 gray scale U/pixel. Early systole was associated with a rapid decrease in left ventricular contrast intensity with near total disappearance of contrast by end-systole (from 23 +/- 33 and 17 +/- 23 U/pixel at end-systole to 6 +/- 10 and 3 +/- 2 at end-systole at the left ventricular base and apex, respectively; p < 0.05). None of the injections resulted in myocardial contrast enhancement by visual or quantitative analysis. Thus, left ventricular contrast echocardiography can be achieved after intravenous injections of sonicated albumin. Transpulmonary left ventricular contrast echocardiography is associated with near total disappearance of contrast during systole. This may be secondary to the destruction of microbubbles by the high left ventricular systolic pressure. These findings may help explain the limited success of this technique thus far for myocardial perfusion imaging.
引用
收藏
页码:1603 / 1607
页数:5
相关论文
共 18 条
[1]  
ARMSTRONG WF, 1988, CIRCULATION S2, V78, P565
[2]   ECHOCARDIOGRAPHIC IMAGING OF THE LEFT-VENTRICLE BY PERIPHERAL INTRAVENOUS-INJECTION OF ECHO CONTRAST AGENT [J].
BERWING, K ;
SCHLEPPER, M .
AMERICAN HEART JOURNAL, 1988, 115 (02) :399-408
[3]  
DICK CD, 1988, CIRCULATION S2, V78, P565
[4]   TWO-DIMENSIONAL CONTRAST ECHOCARDIOGRAPHY .1. INVITRO DEVELOPMENT AND QUANTITATIVE-ANALYSIS OF ECHO CONTRAST AGENTS [J].
FEINSTEIN, SB ;
TENCATE, FJ ;
ZWEHL, W ;
ONG, K ;
MAURER, G ;
TEI, C ;
SHAH, PM ;
MEERBAUM, S ;
CORDAY, E .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1984, 3 (01) :14-20
[5]  
Feinstein SB., 1988, CIRCULATION S2, V78, P565
[6]  
GOTTLIEB S, 1990, J AM SOC ECHO, V3, P238
[7]   SUCCESSFUL LEFT-VENTRICULAR OPACIFICATION FOLLOWING PERIPHERAL VENOUS INJECTION OF SONICATED CONTRAST AGENT - AN EXPERIMENTAL EVALUATION [J].
KELLER, MW ;
FEINSTEIN, SB ;
WATSON, DD .
AMERICAN HEART JOURNAL, 1987, 114 (03) :570-575
[8]   WHY DO THE LUNGS CLEAR ULTRASONIC CONTRAST [J].
MELTZER, RS ;
TICKNER, EG ;
POPP, RL .
ULTRASOUND IN MEDICINE AND BIOLOGY, 1980, 6 (03) :263-&
[9]  
MELTZER RS, 1980, BRIT HEART J, V44, P390
[10]   TRANSMISSION OF ULTRASONIC CONTRAST THROUGH THE LUNGS [J].
MELTZER, RS ;
SARTORIUS, OEH ;
LANCEE, CT ;
SERRUYS, PW ;
VERDOUW, PD ;
ESSED, CE ;
ROELANDT, J .
ULTRASOUND IN MEDICINE AND BIOLOGY, 1981, 7 (04) :377-384