COMPARISON OF LYSIMETER TYPES IN COLLECTING MICROBIAL CONSTITUENTS FROM SEWAGE EFFLUENT

被引:10
作者
KREJSL, J
HARRISON, R
HENRY, C
TURNER, N
TONE, D
机构
[1] UNIV WASHINGTON,COLL FOREST RESOURCES,AR-10,SEATTLE,WA 98195
[2] PIERCE CTY HLTH DEP,TACOMA,WA 98408
[3] UNIV WASHINGTON,COLL FOREST RESOURCES,SEATTLE,WA 98195
关键词
D O I
10.2136/sssaj1994.03615995005800010018x
中图分类号
S15 [土壤学];
学科分类号
0903 ; 090301 ;
摘要
There are no standard methods of determining the impact of septic systems on contamination of groundwater aquifers. Sampling of water for microbiological properties in unsaturated soil is particularly difficult. Successful water sampling devices should collect large amounts of percolating water with minimal change in chemical and biological properties of the water. This laboratory study compared the effectiveness of four types of soil water sampling devices for qualitative sampling of water, using total coliform, fecal coliform, and fecal streptococcus as the primary indicators of water quality. The devices tested were: (i) high-flow ceramic tension lysimeter, (ii) high-flow fritted glass tension lysimeter, (iii) sand-filled lysimeters, and (iv) perforated-tube wells. A constant source of vacuum (0.01 MPa) was applied to all devices to collect water samples. High-flow ceramic tension lysimeters collected adequate volumes of water (an average of 0.340 L after 6 h) but excessive filtering led to underestimation of microbial numbers (only 6% of total coliform, 2.2% of fecal coliform, and no fecal streptococcus were collected). Perforated-tube wells did not collect any water under partially saturated soil conditions; collection occurred only below the water table. Sand-filled lysimeters showed the best combination of volume collection (an average of 0.660 L after 6 h) with good estimation of microbial numbers (90% for total coliform, 83% for fecal coliform, and 45% for fecal streptococcus).
引用
收藏
页码:131 / 133
页数:3
相关论文
共 11 条
[1]   COMPARISON BETWEEN SUCTION AND FREE-DRAINAGE SOIL SOLUTION SAMPLERS [J].
BARBEE, GC ;
BROWN, KW .
SOIL SCIENCE, 1986, 141 (02) :149-154
[2]  
BROWN, 1985, CLOVER CHAMBERS CREE
[3]  
COLE D. W., 1961, SOIL SCI SOC AMER PROC, V25, P321
[4]  
COLE D. W., 1958, SOIL SCI, V85, P293, DOI 10.1097/00010694-195806000-00001
[5]   VALIDITY OF SOIL-WATER SAMPLES COLLECTED WITH POROUS CERAMIC CUPS [J].
HANSEN, EA ;
HARRIS, AR .
SOIL SCIENCE SOCIETY OF AMERICA JOURNAL, 1975, 39 (03) :528-536
[6]  
KOHNKE H, 1940, USDA MISC PUBL, V372
[7]  
PARIZEK R. R., 1970, Journal of Hydrology, V11, P1, DOI 10.1016/0022-1694(70)90111-3
[8]  
REEVE R. C., 1965, SOIL SCI, V99, P339, DOI 10.1097/00010694-196505000-00008
[9]  
WAGNER GEORGE H., 1962, SOIL SCI, V94, P379, DOI 10.1097/00010694-196212000-00005
[10]   TECHNIQUE USING POROUS CUPS FOR WATER SAMPLING AT ANY DEPTH IN UNSATURATED ZONE [J].
WOOD, WW .
WATER RESOURCES RESEARCH, 1973, 9 (02) :486-488