EFFECTS OF DIOPTRIC BLUR ON SNELLEN AND GRATING ACUITY

被引:70
作者
THORN, F
SCHWARTZ, F
机构
[1] New England College of Optometry, Boston, MA
关键词
Blur; Grating acuity; Refractive error; Snellen acuity; Spurious resolution;
D O I
10.1097/00006324-199001000-00002
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
We compared the effects of dioptric blur on Snellen acuity and grating acuity. Dioptric blur had a strong negative effect on Snellen acuity, consistent with previous studies, but had little effect on grating acuity. Between 1 and 12 D both types of acuity were reduced as a linear function of blur. However, 12 D of blur reduced grating acuity to only 6/24 (20/80), whereas letter acuity was worse than 6/300 (20/1000). We suggest that these differences are due to the presence of “spurious resolution” in which phase-reversed gratings are readily detectable. But the phase reversals so distort the relative positions of linear segments within the letters that the letters become unrecognizable. These results indicate that Snellen letters are more sensitive than gratings to a patient’s refractive errors, emphasize the differences between Snellen and grating acuity, and indicate that the minimum angle of resolution (MAR) concept is not applicable to letters. © 1990 American Academy of Optometry.
引用
收藏
页码:3 / 7
页数:5
相关论文
共 32 条
[1]  
Sloan L.L., Measurement of visual acuity: A critical review, Arch Ophthalmol, 45, pp. 704-725, (1951)
[2]  
Teller D.Y., Morse R., Borton R., Regal D., Visual acuity for vertical and diagonal gratings in human infants, Vision Res, 14, pp. 1433-1439, (1974)
[3]  
Gwiazda J., Brill S., Mohindra I., Held R., Infant visual acuity and its meridional variation, Vision Res, 18, pp. 1557-1564, (1978)
[4]  
Green D.G., Testing the vision of cataract patients by means of laser-generated interference fringes, Science, 168, pp. 1240-1242, (1970)
[5]  
Cavonius C.R., Hilz R., A technique for testing visual function in the presence of opacities, Invest Ophthalmol, 12, pp. 933-936, (1973)
[6]  
Levi D.M., Klein S., Differences in vernier discrimination for gratings between strabismic and anisometropic amblyopes, Invest Ophthalmol Vis Sci, 23, pp. 398-407, (1982)
[7]  
Levi D.M., Klein S., Vernier acuity, crowding and amblyopia, Vision Res, 25, pp. 979-991, (1985)
[8]  
Levi D.M., Klein S., Aitsebaomo A.P., Vernier acuity, crowding and cortical magnification, Vision Res, 25, pp. 963-977, (1985)
[9]  
Schlaer S., The relation between visual acuity and illumination, J Gen Physiol, 21, pp. 165-188, (1937)
[10]  
Green D.G., Campbell F.W., Effect of focus on the visual response to a sinusoidally modulated spatial stimulus, J Opt Soc Am, 55, pp. 1154-1157, (1965)