Steady-state analysis of multi-stage flash desalination process

被引:81
作者
ElDessouky, H
Shaban, HI
AlRamadan, H
机构
[1] Department of Chemical Engineering, Kuwait University, 13060 Safat
关键词
multi-stage flash desalination; thermal analysis of MSF process; modelling of MSF plants; parametric study of the MSF desalination process;
D O I
10.1016/0011-9164(95)00080-1
中图分类号
TQ [化学工业];
学科分类号
0817 ;
摘要
The multi-stage flash (MSF) water desalination process plays a vital role in the provision of fresh water in many areas of the world, particularly in the Arab Gulf countries. This paper describes a steady-state mathematical model developed to analyze the MSF water desalination process. Relationships between parameters controlling the product water cost (e.g., thermal performance ratio, specific heat transfer surface area, and specific flow rate of cooling water and recirculated brine) to other operating and design variables are established. These relationships can be used to design new plants or to analyze already existing units. The model assumes the practical case of constant heat transfer surface area per stage in each section. It considered the variation of the physical properties of water with temperature and salt concentration, the effect of fouling factors and presence of non-condensable gases on the overall heat transfer coefficients, and variations in stage flash down and thermodynamic loss from stage to stage. The model also takes into consideration the heat transfer losses from the stages to the surroundings and through rejection of the noncondensable gases. The results obtained from the model developed are compared with data from six different MSF plants. Good agreement is obtained between data of these plants and model predictions.
引用
收藏
页码:271 / 287
页数:17
相关论文
共 20 条
[1]  
ALMUDAIHEEM AM, 1993, DESALINATION, V92, P1
[2]  
[Anonymous], 1986, DESALINATION PROCESS
[3]  
BARBA D, 1973, 4TH INT S FRESH WAT, V1, P153
[4]   THERMAL-ANALYSIS OF MULTISTAGE FLASH DESALTING SYSTEMS [J].
DARWISH, MA .
DESALINATION, 1991, 85 (01) :59-79
[5]  
ELDESSOUKY HT, 1985, 3RD P JOINT C MECH E
[6]   SOME THOUGHTS ON THE LIMITATIONS ON INCREASING THE UNIT SIZES OF CONVENTIONAL CROSS-TUBE MSF DISTILLATION PLANTS [J].
HANBURY, WT .
DESALINATION, 1993, 93 (1-3) :127-145
[7]   A TRIDIAGONAL MATRIX MODEL FOR MULTISTAGE FLASH DESALINATION PLANTS [J].
HELAL, AM ;
MEDANI, MS ;
SOLIMAN, MA ;
FLOWER, JR .
COMPUTERS & CHEMICAL ENGINEERING, 1986, 10 (04) :327-342
[8]   OPERATIONAL OPTIMIZATION OF MSF SYSTEMS [J].
HORNBURG, CD ;
WATSON, BM .
DESALINATION, 1993, 92 (1-3) :333-351
[9]  
HORNBURG CD, 1993, DESALINATION WATER R, V2, P22
[10]  
HUSSAIN A, 1993, DESALINATION, V92, P21