X-RAY-IMAGING USING AMORPHOUS SELENIUM - FEASIBILITY OF A FLAT-PANEL SELF-SCANNED DETECTOR FOR DIGITAL RADIOLOGY

被引:260
作者
ZHAO, W
ROWLANDS, JA
机构
[1] Department of Medical Biophysics, University of Toronto, Reichmann Research Building, Sunnybrook Health Science Centre, Toronto, M4N 3M5
关键词
DIAGNOSTIC X-RAY IMAGING; DIGITAL RADIOLOGY; AMORPHOUS SELENIUM; SOLID-STATE IMAGERS; FLAT-PANEL IMAGERS;
D O I
10.1118/1.597628
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
We investigate a concept for making a large area, flat-panel detector for digital radiology. It employs an x-ray sensitive photoconductor to convert incident x-radiation to a charge image which is then electronically read but with a large area integrated circuit. The large area integrated circuit, also called an active matrix, consists of a two-dimensional array of thin film transistors (TFTs). The potential advantages of the hat-panel detector for digital radiography include: instantaneous digital radiographs without operator intervention; compact size approaching that of a screen-film cassette and thus compatibility with existing x-ray equipment; high quantum efficiency combined with high resolution. Its potential advantages over the x-ray image intensifier (XRII)/video systems for fluoroscopy include: compactness; geometric accuracy; high resolution, and absence of veiling glare. The feasibility of the detector for digital radiology was investigated using the properties of a particular photoconductor (amorphous selenium) and active matrix array (with cadmium selenide TFTs). The results showed that it can potentially satisfy the,detector design requirements for radiography (e.g., chest radiography and mammography). For fluoroscopy, the images can be obtained in real-time but the detector is not quantum noise Limited below the mean exposure rate typically used in fluoroscopy. Possible improvements in x-ray sensitivity and noise performance for the application in fluoroscopy are discussed.
引用
收藏
页码:1595 / 1604
页数:10
相关论文
共 43 条
  • [1] ANTONUK LE, 1993, MATER RES SOC SYMP P, V297, P945, DOI 10.1557/PROC-297-945
  • [2] DEMONSTRATION OF MEGAVOLTAGE AND DIAGNOSTIC-X-RAY IMAGING WITH HYDROGENATED AMORPHOUS-SILICON ARRAYS
    ANTONUK, LE
    BOUDRY, J
    HUANG, WD
    MCSHAN, DL
    MORTON, EJ
    YORKSTON, J
    LONGO, MJ
    STREET, RA
    [J]. MEDICAL PHYSICS, 1992, 19 (06) : 1455 - 1466
  • [3] ANTONUK LE, 1992, P SOC PHOTO-OPT INS, V1651, P94, DOI 10.1117/12.59387
  • [4] XERORADIOGRAPHY
    BOAG, JW
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 1973, 18 (01) : 3 - 37
  • [5] ENERGY AND ANGULAR-DEPENDENCE OF X-RAY ABSORPTION AND ITS EFFECT ON RADIOGRAPHIC RESPONSE IN SCREEN-FILM SYSTEMS
    CHAN, HP
    DOI, K
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 1983, 28 (05) : 565 - 579
  • [6] Chenette R.E., 1967, ADV ELECTRON EL P, V23, P303, DOI [10.1016/S0065-2539(08)60062-1, DOI 10.1016/S0065-2539(08)60062-1]
  • [7] CHO GS, 1990, MATER RES SOC SYMP P, V192, P393, DOI 10.1557/PROC-192-393
  • [8] DEWERD LA, 1984, CRC HDB MED PHYSICS, V2, P123
  • [9] DIGITAL IMAGING OF THE CHEST
    FRASER, RG
    SANDERS, C
    BARNES, GT
    MACMAHON, H
    GIGER, ML
    DOI, K
    TEMPLETON, AW
    COX, GG
    DWYER, SJ
    MERRITT, CRB
    JONES, JP
    [J]. RADIOLOGY, 1989, 171 (02) : 297 - 307
  • [10] HIGH-SENSITIVITY READOUT OF 2D A-SI IMAGE SENSORS
    FUJIEDA, I
    STREET, RA
    WEISFIELD, RL
    NELSON, S
    NYLEN, P
    PEREZMENDEZ, V
    CHO, GS
    [J]. JAPANESE JOURNAL OF APPLIED PHYSICS PART 1-REGULAR PAPERS SHORT NOTES & REVIEW PAPERS, 1993, 32 (1A): : 198 - 204