3-DIMENSIONAL RECORDING AND DESCRIPTION OF MOTIONS OF THE SHOULDER MECHANISM

被引:172
作者
VANDERHELM, FCT
PRONK, GM
机构
[1] Man-Machine Systems Group, Lab. for Measurement and Control, Departnnent of Mechanical Engineering and Marine Technology, Delft University of Technology, Delft, 2628 CD
来源
JOURNAL OF BIOMECHANICAL ENGINEERING-TRANSACTIONS OF THE ASME | 1995年 / 117卷 / 01期
关键词
D O I
10.1115/1.2792267
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
A measurement technique is presented for recording positions of the bones of the shoulder mechanism, i.e., thorax, clavicula, scapula and humerus, in 3-D space, based on palpating and recording positions of bony landmarks. The palpation technique implies that only static positions can be measured. Accuracy of retrieving bony landmarks is checked on-line using rigid body assumptions. The measurement error is calculated afterwards and is comparable with cinegraphic methods. Axial rotation of the clavicula is estimated by minimizing rotations in the acromioclnviacularjoint. A number of motion definitions is compared by means of interindividual variation and subjective interpretability. Two useful definitions are proposed for describing motions of the shoulder mechanism. Four conditions have been recorded: abduction and anteflexion of the humerus both with and without additional weight in the hand. Abduction and anteflexion result in large differences in scapular and clavicular motions. The effect of additional weight in the hand on the position of the shoulder girdle is negligible.
引用
收藏
页码:27 / 40
页数:14
相关论文
共 49 条
[1]   APPLICATION OF A MAGNETIC TRACKING DEVICE TO KINESIOLOGIC STUDIES [J].
AN, KN ;
JACOBSEN, MC ;
BERGLUND, LJ ;
CHAO, EYS .
JOURNAL OF BIOMECHANICS, 1988, 21 (07) :613-&
[2]   3-DIMENSIONAL KINEMATICS OF GLENOHUMERAL ELEVATION [J].
AN, KN ;
BROWNE, AO ;
KORINEK, S ;
TANAKA, S ;
MORREY, BF .
JOURNAL OF ORTHOPAEDIC RESEARCH, 1991, 9 (01) :143-149
[3]  
BAGG SD, 1988, AM J PHYS MED REHAB, V67, P238
[4]   GLENOHUMERAL ELEVATION STUDIED IN 3 DIMENSIONS [J].
BROWNE, AO ;
HOFFMEYER, P ;
TANAKA, S ;
AN, KN ;
MORREY, BF .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1990, 72 (05) :843-845
[5]  
CAPOZZO A, 1988, 6TH P M EUR SOC BIOM, pC23
[6]  
CASOLO F, 1987, BIOMECHANICS B, V11, P1062
[7]  
CONWAY AM, 1961, PHYS THER REV, V11, P421
[8]   MEASUREMENT ERRORS IN ROENTGEN-STEREOPHOTOGRAMMETRIC JOINT-MOTION ANALYSIS [J].
DELANGE, A ;
HUISKES, R ;
KAUER, JMG .
JOURNAL OF BIOMECHANICS, 1990, 23 (03) :259-269
[9]  
DOODY S G, 1970, Archives of Physical Medicine and Rehabilitation, V51, P711
[10]  
DOODY S G, 1970, Archives of Physical Medicine and Rehabilitation, V51, P595